Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Not GLP but well documented

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: ISO 2591-1
Principles of method if other than guideline:
A dry sieving technique was applied to determine the particle size distribution of the test substance. Each trial was performed with around 100 g of substance. Nine metal wire sieves with calibrated meshes (4 750, 3 360, 2 380, 1 700, 1 190, 833, 600, 417 and 125 µm) were stacked and submitted to automatic vertical vibrations during 30 min. Each sieve was weighed before and after sieving. Three replicates were performed according to GRAN-94003 (internal method based on ISO 2591-1).
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
reaction mass of calcium sulfate,magnesium dihydroxide,calcium carbonate
IUPAC Name:
reaction mass of calcium sulfate,magnesium dihydroxide,calcium carbonate
Details on test material:
Batch number: SOLVCAT
Samplilng date: 2 September 2009

Results and discussion

Particle size
Percentile:
D50
Mean:
ca. 2 990 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.

Any other information on results incl. tables

Table 1 :individual values, mean value and standard deviation obtained for oversize (retained fraction) on each sieve

Sieve mesh (µm)

Trial 1

Oversize (%)

Trial 2

Oversize (%)

Trial 3

Oversize (%)

Mean value (%)

Standard deviation (%)

4 750

3.79

3.73

3.52

3.68

0.14

3 360

32.86

30.52

33.43

32.3

1.5

2 380

42.09

41.84

40.37

41.4

0.9

1 700

14.99

16.19

15.23

15.5

0.6

1 190

5.57

6.84

6.56

6.3

0.7

833

0.19

0.21

0.23

0.21

0.02

600

0.14

0.24

0.23

0.20

0.06

417

0.07

0.10

0.13

0.10

0.03

125

0.10

0.16

0.14

0.13

0.03

0

0.19

0.17

0.16

0.17

0.02

 

Applicant's summary and conclusion

Executive summary:

 

D50 (µm)

D10 (µm)

D90 (µm)

Trial 1

3 011.85

1 848.56

4 449.11

Trial 2

2 951.01

1 782.43

4 424.03

Trial 3

3 005.65

1 798.69

4 441.83

Mean value

2 990

1 810

4 438

Standard deviation

30

30

13