Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
According to OECD 209 and GLP
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
GLP compliance:
yes
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
Preparation of the saturated solution: The test item was weighed out (1000 mg/L ) directly into an Erlenmeyer flask and filled up with 250 mL autoclaved tap water. It was stirred for 24 h.
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Origin: Municipal sewage treatment plant of D-31157 Sarstedt
- non-adapted activated sludge, receives predominatly municipal sewage and hardly industrial chemical waste
- Preatreatment: the sludge was washed twice with autoclaved tap water and adjusted corresponding to a dry weight of 4.0 g/L ± 10 %
Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h
Remarks on exposure duration:
A range-finding test (Non-GLP-state9 was carried out with the concentrations: 10 - 100 - 1000 mg/L). Based on the results of the preliminary test the study was carried out with the limit test concentration of 1000 mg/L.
Test temperature:
20.2°C
pH:
6,84
Dissolved oxygen:
7.25 mg/L
Nominal and measured concentrations:
Nominal concentration: 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel:
- Erlenmeyer flasks, DIN 12380
- fill volume: 500 mL
- Aeration: permanent
- No. of vessels per concentration (replicates): 1
- No. of vessels per control (replicates): 2

TEST MEDIUM
- 200 mL inoculum
- 16 mL synthetic waste water
- 284 mL autoclaved tap water
- test item concentration (directly weighing)

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
- the pH-value of the activated sludge was measured prior to testing
- the temperature in the measuring cell was determined once durcing the measurement
- the room temperature during the test was recorded continously by a hygrothermograph

TEST CONCENTRATIONS
- Range finding study
- Test concentrations: 10 mg/L, 100 mg/L, 1000 mg/L
- Results used to determine the conditions for the definitive study: based on the results of the preliminary test the study was carried out with a
limit test concentration of 1000 mg/L. Two control replicates without test item were included.
Reference substance (positive control):
yes
Remarks:
copper(II)-sulphate-pentahydrate
Duration:
3 h
Dose descriptor:
LOEC
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Results with reference substance (positive control):
In the reference test the EC50-value for copper(II)-sulphate-pentahydrate was calculated by probit analysis usiing software SIGMAPLOT.
EC50 (3 h) = 93 mg/L
The two control respiration rates differ not more than 15 % in the study.
The EC50 (3 h) of copper(II)-sulphate-pentahydrate is in the accekpted range of 53 - 155 mg/L.

Respiration Rates and Inhibition of Respiration of Test and Reference item concentrations

 

concentration

[mg/L]

respiration rate

[mg O2/L x h

inhibition

[%]

test item

1000

38.4

7

control 1

-

30.0

-

control 2

-

31.2

-

reference item

180

8.0

74

 

100

12.4

59

 

58

22.0

28

Validity criteria fulfilled:
yes
Conclusions:
The test item is not toxic at concentrations ≤ 1000 mg/L to activated sludge of a municipal sewage treatment plant.
Executive summary:

A Respiration Inhibition Test with activated sludge according to OECD Guideline No. 209 was performed with the test item. Test system was activated sludge of a municipal treatment plant. The test was performed under static conditions with the nominal limit concentration of 1000 mg/L. The respiration rates of control, reference and test item concentrations were measured after a contact time of three hours, and the inhibitory effects of the test and reference concentrations were determined in comparison to the control respiration rates. No inhibition of the test item was observed at the tested concentration.

In order to check the activity of the test system and the test conditions a reference test was carried out with copper-(II)-sulphate-pentahydrate as reference item and the reference toxicity was determined. The EC50- value for the reference item was 93 mg/L.

Validity criteria of the test guideline were fulfilled.

The test item is not toxic at concentrations ≤ 1000 mg/L to activated sludge of a municipal sewage treatment plant.

Endpoint:
activated sludge respiration inhibition testing
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reason / purpose for cross-reference:
read-across source
Duration:
3 h
Dose descriptor:
LOEC
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Results with reference substance (positive control):
In the reference test the EC50-value for copper(II)-sulphate-pentahydrate was calculated by probit analysis usiing software SIGMAPLOT.
EC50 (3 h) = 93 mg/L
The two control respiration rates differ not more than 15 % in the study.
The EC50 (3 h) of copper(II)-sulphate-pentahydrate is in the accekpted range of 53 - 155 mg/L.

Respiration Rates and Inhibition of Respiration of Test and Reference item concentrations

 

concentration

[mg/L]

respiration rate

[mg O2/L x h

inhibition

[%]

test item

1000

38.4

7

control 1

-

30.0

-

control 2

-

31.2

-

reference item

180

8.0

74

 

100

12.4

59

 

58

22.0

28

Validity criteria fulfilled:
yes
Conclusions:
The test item is not toxic at concentrations ≤ 1000 mg/L to activated sludge of a municipal sewage treatment plant.
Executive summary:

A Respiration Inhibition Test with activated sludge according to OECD Guideline No. 209 was performed with the test item. Test system was activated sludge of a municipal treatment plant. The test was performed under static conditions with the nominal limit concentration of 1000 mg/L. The respiration rates of control, reference and test item concentrations were measured after a contact time of three hours, and the inhibitory effects of the test and reference concentrations were determined in comparison to the control respiration rates. No inhibition of the test item was observed at the tested concentration.

In order to check the activity of the test system and the test conditions a reference test was carried out with copper-(II)-sulphate-pentahydrate as reference item and the reference toxicity was determined. The EC50- value for the reference item was 93 mg/L.

Validity criteria of the test guideline were fulfilled.

The test item is not toxic at concentrations ≤ 1000 mg/L to activated sludge of a municipal sewage treatment plant.

Description of key information

A Respiration Inhibition Test with activated sludge according to OECD Guideline No. 209 was performed with the test item. Test system was activated sludge of a municipal treatment plant. The test was performed under static conditions with the nominal limit concentration of 1000 mg/L. The respiration rates of control, reference and test item concentrations were measured after a contact time of three hours, and the inhibitory effects of the test and reference concentrations were determined in comparison to the control respiration rates. No inhibition of the test item was observed at the tested concentration.

In order to check the activity of the test system and the test conditions a reference test was carried out with copper-(II)-sulphate-pentahydrate as reference item and the reference toxicity was determined. The EC50- value for the reference item was 93 mg/L. Validity criteria of the test guideline were fulfilled.

The test item is not toxic at concentrations ≤ 1000 mg/L to activated sludge of a municipal sewage treatment plant.

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L

Additional information