Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 270-695-5 | CAS number: 68476-55-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Boiling point
Administrative data
Link to relevant study record(s)
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP status not known, guideline study, available as an unpublished report, reliable with restrictions
- Qualifier:
- according to guideline
- Guideline:
- other: EN ISO 3405
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D 86
- Deviations:
- no
- GLP compliance:
- not specified
- Type of method:
- other: Not specified
- Boiling pt.:
- > 25 - < 48 °C
- Atm. press.:
- 1 013 hPa
- Decomposition:
- no
- Conclusions:
- The boiling point of substance 102110-14-5 is 25 - 48 °C.
- Executive summary:
This is a guideline study and is considered reliable and suitable for use for this endpoint. The boiling point of substance 102110-14-5 is 25 - 48 °C.
- Endpoint:
- boiling point
- Type of information:
- calculation (if not (Q)SAR)
- Remarks:
- Migrated phrase: estimated by calculation
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP status not known, guideline study, experimental study. No restrictions, fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- other: OECD 104
- Principles of method if other than guideline:
- Normal boiling temperature was deducted from vapour pressure data by static method according to OECD guideline 104
- GLP compliance:
- not specified
- Type of method:
- other: calculated
- Boiling pt.:
- 101.9 °C
- Atm. press.:
- 1 013.25 Pa
- Decomposition:
- no
- Conclusions:
- The boiling point was calculated as 101.9°C at 1013.25 hPa.
- Executive summary:
Although the GLP status of this study is not known, it follows a standard guideline and is considered reliable for this endpoint. The boiling point was calculated as 101.9°C at 1013.25 hPa.
- Endpoint:
- boiling point
- Type of information:
- calculation (if not (Q)SAR)
- Remarks:
- Migrated phrase: estimated by calculation
- Adequacy of study:
- key study
- Study period:
- 08/12/2008 - 08/04/2009
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP compliant, guideline study, experimental study. No restrictions, fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- other: OECD 104
- Principles of method if other than guideline:
- As this is a mixture of substances of different volatility, the dynamic method according to OECD guideline 103 is not suitable. The normal boiling temperature was calculated from vapour pressure data by static method according to OECD guideline 104.
- GLP compliance:
- yes
- Type of method:
- other: calculated
- Boiling pt.:
- 71.27 °C
- Atm. press.:
- 1 013.25 hPa
- Decomposition:
- no
- Conclusions:
- The normal boiling temperature of the substance is 71.27 °C at 1013.25 hPa.
- Executive summary:
The study is GLP compliant and was carried out to a standard guideline, therefore the data is considered reliable. The normal boiling temperature of the substance is 71.27 °C at 1013.25 hPa.
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 06/06/2007 - 16/10/2007
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP compliant, guideline study, available as unpublished report, no restrictions fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- other: OECD Guideline 104
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- dynamic method
- Boiling pt.:
- 44.8 °C
- Atm. press.:
- 1 013 hPa
- Decomposition:
- no
- Conclusions:
- The boiling point of 68476-55-1 is 44.8°C.
- Executive summary:
This study was conducted to a standard guideline and according to GLP and so is considered fully reliable for use as a key study. The boiling point of 68476-55-1 is 44.8°C.
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 23/10/2007 - 04/03/2008
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP compliant,guideline study, available as unpublished report, no restrictions, fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- other: OECD Test Guideline 104
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- other: static
- Boiling pt.:
- 73.4 °C
- Atm. press.:
- 1 013.25 hPa
- Decomposition:
- no
- Conclusions:
- The boiling point of 92128-65-9 is 73.4°C.
- Executive summary:
This study was conducted to a standard guideline and according to GLP and so is considered fully reliable for use as a key study. The boiling point of 92128-65-9 is 73.4°C.
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP406
- Principles of method if other than guideline:
- Boiling point range determined by Gas Chromatography
- GLP compliance:
- no
- Remarks:
- Study methods are UKAS accredited
- Type of method:
- other: Boiling point determined by Gas Chromatography
- Specific details on test material used for the study:
- Test material composition is reflected in the boundary composition and legal entity composition.
- Key result
- Boiling pt.:
- >= 25.5 - <= 98 °C
- Atm. press.:
- 1 atm
- Conclusions:
- The boiling point of the substance is 25.5 - 98 ºC.
- Executive summary:
The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be 25.5 - 98 ºC.
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP406
- Principles of method if other than guideline:
- Boiling point range determined by Gas Chromatography
- GLP compliance:
- no
- Remarks:
- Study methods are UKAS accredited
- Type of method:
- other: Boiling point determined by Gas Chromatography
- Specific details on test material used for the study:
- Test material composition is reflected in the boundary composition and legal entity composition.
- Key result
- Boiling pt.:
- >= 62 - <= 99 °C
- Atm. press.:
- 1 atm
- Conclusions:
- The boiling point of the substance is 62 - 99ºC.
- Executive summary:
The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be 62 - 99ºC
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP406
- Principles of method if other than guideline:
- Boiling point range determined by Gas Chromatography
- GLP compliance:
- no
- Remarks:
- Study methods are UKAS accredited
- Type of method:
- other: Boiling point determined by Gas Chromatography
- Specific details on test material used for the study:
- Test material composition is reflected in the boundary composition and legal entity composition.
- Key result
- Boiling pt.:
- >= 21 - <= 81.5 °C
- Atm. press.:
- 1 atm
- Conclusions:
- The boiling point of the substance is 21 - 81.5 ºC.
- Executive summary:
The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be 21 - 81.5 ºC.
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP406
- Principles of method if other than guideline:
- Boiling point range determined by Gas Chromatography
- GLP compliance:
- no
- Remarks:
- Study methods are UKAS accredited
- Type of method:
- other: Boiling point determined by Gas Chromatography
- Specific details on test material used for the study:
- Test material composition is reflected in the boundary composition and legal entity composition.
- Key result
- Boiling pt.:
- >= -3.5 - <= 103 °C
- Atm. press.:
- 1 atm
- Conclusions:
- The boiling point of the substance is -3.5 - 103ºC.
- Executive summary:
The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be -3.5 - 103ºC.
Referenceopen allclose all
The normal boiling point was deduced from the vapour pressure data by interpolation
The normal boiling point was deduced from the vapour pressure data by interpolation
Description of key information
The boiling point of streams in this category is in the range -3.5°C to 103°C.
Key value for chemical safety assessment
- Boiling point at 101 325 Pa:
- 58 °C
Additional information
Data are available for all six streams in this category (64741-84-0: 101.9°C, 64742-49-0: 71.27°C, 92128-65-9: 73.4°C, 68476-55-1: 44.8°C, 102110-14-5: 25 - 48°C) from Chilworth Technology Limited (2009), BASF (2009), GKA competence centre analytics (2009, 2009, 2009) and Deutsche Shell Chemie (2009).
New data areavilable for 4 streams in this category from Intertek (2018):
EC# 265-086-6: 25.5 - 98 ºC,
EC# 265-151-9: 62 - 99ºC,
EC# 295-762-6: -3.5 - 103ºC,
EC# 270-695-5: 21 - 81.5 ºC.
These data will be read across to all category members. The mean of the boiling point values for the category is 53.0°C and this has been used to complete the 'key value for chemical safety assessment'.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.