Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 26 September 2000 to February 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Reason / purpose for cross-reference:
reference to other study
Reason / purpose for cross-reference:
reference to other study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
static method
Test no.:
#1
Temp.:
37 °C
Vapour pressure:
202.9 Pa
Test no.:
#2
Temp.:
40.8 °C
Vapour pressure:
611.2 Pa
Test no.:
#3
Temp.:
51 °C
Vapour pressure:
754.6 Pa
Test no.:
#4
Temp.:
30.8 °C
Vapour pressure:
229.6 Pa
Test no.:
#5
Temp.:
36 °C
Vapour pressure:
262 Pa
Test no.:
#6
Temp.:
45.5 °C
Vapour pressure:
325.5 Pa

The corrected vapour pressures were plotted in a Clausius-Clapeyron plot (log p [p in Pa] versus 1/T [T in K]). All the experimental data have been used for this regression.

Interpolation using this regression function yields an estimated vapour pressure of 108.9 Pa at 20°C and 150.9 at 25°C.

Conclusions:
The test item vapour pressure is estimated to be 108.9 Pa at 20°C and 150.9 Pa at 25°C.
Executive summary:

The test item vapour pressure was determined with the static method according to recognised guideline under GLP. No deviation from the guideline was observed in the study.

Experimental vapour pressures have been measured between 30.8°C and 51°C. The data obtained have been used to build a Clausius-Clapeyron plot (log p [p in Pa] versus 1/T [T in K]). All the experimental data have been used for this regression.

Interpolation using this regression function yields an estimated vapour pressure of 108.9 Pa at 20°C and 150.9 at 25°C.

Description of key information

The vapour pressure of the test item was determined in an experimental key study of Klimisch validity 1.

Key value for chemical safety assessment

Vapour pressure:
108.9 Pa
at the temperature of:
20 °C

Additional information