Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10. May to 15. August 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study performed according to OECD guideline but not under GLP conditions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Reference substance name:
Absorbent A2
IUPAC Name:
Absorbent A2
Details on test material:
- Name of test material (as cited in study report): Absorbent A2
- Substance type: UVCB
- Physical state: Brown liquid
- Stability under test conditions: months
- Storage condition of test material: room temperature, in the dark

Results and discussion

Boiling point
Boiling pt.:
ca. 70 - 400 °C
Atm. press.:
1 013.3 hPa
Decomposition:
no

Any other information on results incl. tables

Boiling Point / Boiling Range (DSC)

Two measurements in aluminium crucibles with a hole showed broad endothermic signals. Due to the broad shape of the endothermic signals only temperature ranges but no defined onset temperatures can be derived. A correctionof the values to standard atmospheric pressure wasdeemed unnecessarybecause theatmospheric pressure during the tests was 1022 hPa and therefore the resulting correction is much smaller than the uncertainty that accompanies the evaluation of the broadendothermic signals.

The measurements showed a broad endothermic effect in the temperature range 70 °C to 380 °C.

Ident-No.

Test temperature range

 / °C

Temperature range of

endothermic signal / °C

Crucible

31767

20 - 500

70 – 380

Aluminium with a hole

31768

20 - 500

70 – 400

Aluminium with a hole

 

According to the information from the sponsor the test item consists of a large number of different chemical substances. This composition from many chemical substances of the test item is most likely the reason that no distinctive boiling point could be observed.

The test item has a boiling range at atmospheric pressure (1013.3 hPa) ofapproximately 70 °C to 400 °C.

Applicant's summary and conclusion

Conclusions:
The test item has a boiling range at atmospheric pressure (1013.3 hPa) of 70 °C to 400 °C.
Executive summary:

The test item has a boiling range at atmospheric pressure (1013.3 hPa) of 70 °C to 400 °C.