First-aid measures

1 Description of first aid measures

General information:

 Take affected persons out of danger area and lay down.

After inhalation:

 Supply fresh air; consult doctor in case of complaints.

After skin contact:

 Immediately wash with water and soap and rinse thoroughly.

 If skin irritation continues, consult a doctor.

After eye contact:

 Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

 Remove contact lenses, if present and easy to do. Continue rinsing.

After swallowing:

 Rinse out mouth and then drink plenty of water.

 If symptoms persist consult doctor.

2 Most important symptoms and effects, both acute and delayed

 No further relevant information available.

3 Indication of any immediate medical attention and special treatment needed

 No further relevant information available.

Fire-fighting measures

1 Extinguishing media

Suitable extinguishing agents:

 CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

 Use fire extinguishing methods suitable to surrounding conditions.

For safety reasons unsuitable extinguishing agents:

 Water with full jet

2 Special hazards arising from the substance or mixture

 Formation of toxic gases is possible during heating or in case of fire.

In case of fire, the following can be released:

 Carbon monoxide

 Carbon dioxide

 Nitrogen oxides (NOx)

3 Advice for firefighters

Protective equipment:

 Wear self-contained respiratory protective device.

Additional information:

 Cool endangered receptacles with water spray.

 Collect contaminated fire fighting water separately. It must not enter the sewage system.

Accidental release measures

1 Personal precautions, protective equipment and emergency procedures

 Ensure adequate ventilation.

 Wear protective clothing.

 Avoid formation of dust.

 Keep away from ignition sources.

2 Environmental precautions

 Do not allow product to reach sewage system or any water course.

 Do not allow to enter sewers/ surface or ground water.

3 Methods and material for containment and cleaning up

 Pick up mechanically.

 Dispose of the material collected according to regulations.

Handling and storage

1 Precautions for safe handling

 Prevent formation of dust.

 Any unavoidable deposit of dust must be regularly removed.

 Ensure good ventilation/exhaustion at the workplace.

Information about fire and explosion protection:

 Dust can combine with air to form an explosive mixture.

 Keep ignition sources away - Do not smoke.

 Protect against electrostatic charges.

2 Conditions for safe storage, including any incompatibilities

Requirements to be met by storerooms and receptacles:

 Store only in the original receptacle.

Information about storage in one common storage facility:

 Store away from oxidizing agents.

 Do not store together with acids.

Further information about storage conditions:

 Store in cool, dry conditions in well sealed receptacles.

3 Specific end use(s)

 No further relevant information available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not classified
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not classified
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not classified
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not classified
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

1 Control parameters

Ingredients with limit values that require monitoring at the workplace:

 Not required.

2 Exposure controls

General protective and hygienic measures:

 Do not eat, drink, smoke or sniff while working.

 Keep away from foodstuffs, beverages and feed.

 Avoid contact with the eyes and skin.

 The usual precautionary measures are to be adhered to when handling chemicals.

Respiratory protection:

 Not necessary if room is well-ventilated.

Protection of hands:

 The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.

 Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation.

Material of gloves:

 The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

Penetration time of glove material:

 The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye protection:

 Safety glasses

Body protection:

 Protective work clothing

Stability and reactivity

1 Reactivity

 No further relevant information available.

2 Chemical stability

 No decomposition if used and stored according to specifications.

Thermal decomposition / conditions to be avoided:

 No decomposition if used according to specifications.

3 Possibility of hazardous reactions

 No dangerous reactions known.

4 Conditions to avoid

 No further relevant information available.

5 Incompatible materials

 Strong oxidizing agents

 Reacts with strong acids.

6 Hazardous decomposition products

 No dangerous decomposition products known.

Disposal considerations

1 Waste treatment methods

Recommendation:

 Must be specially treated adhering to official regulations.

2 Uncleaned packaging

Recommendation: