Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 October 2022
Reliability:
2 (reliable with restrictions)
Justification for type of information:
Non-GLP study; suitable for registration and classification.
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
no
Specific details on test material used for the study:
No further details in study report
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item RED HF2 is not considered as a flammable solid.
Executive summary:

The purpose of this study is to determine the flammability of test item RED HF2.


The flame from the gas burner was applied to one end of the strip for 2 minutes and the test item did not ignite. Some fume was observed for a few seconds after the flame was stopped. The test item melted in contact with the gas burner.
As no propagation of the combustion (flame or smouldering) along 200 mm within two minutes occurred, the test item is not considered as a flammable solid, and no further testing is carried out.

Description of key information

The test item RED HF2 is not considered as a flammable solid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

As no propagation of the combustion (flame or smouldering) along 200 mm within two minutes occurred, the test item is not considered as a flammable solid, and no further testing is carried out.