Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 AUG 2022 TO 06 OCT 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2022
Report date:
2022

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
2019
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-[(1-[[6-cyano-5-(trifluoromethyl)pyridin-3-yl]carbamoyl]cyclobutyl)amino]-2-fluoro-N-methylbenzamide
Cas Number:
1950587-20-8
Molecular formula:
C20H17F4N5O2
IUPAC Name:
4-[(1-[[6-cyano-5-(trifluoromethyl)pyridin-3-yl]carbamoyl]cyclobutyl)amino]-2-fluoro-N-methylbenzamide
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- lot/batch number of test material: 22CN0611
- Expiry date: 11 May 2023 (retest date)
- Purity test date: 31 May 2022 (certificate of analysis release date)
- Physical Description: Brown powder
- Purity: 99.9%
- Purity correction factor: no correction factor required
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
1 s

Any other information on results incl. tables

In contact with the flame of the gas burner the test material melted, emitted yellow sparks and turned into a black residue. Grey smoke was observed. After removal of the ignition source, no propagation of combustion of the test material was observed.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The preliminary screening test was performed for the determination of the flammability of JNJ-63632335-AAA (T003671).
No propagation of combustion of the test material along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test material is considered ‘not flammable’.