Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 JUL 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: Knudsen cell
Temp.:
20 °C
Vapour pressure:
>= 0 - <= 0 Pa
Temp.:
25 °C
Vapour pressure:
>= 0 - <= 0 Pa

Observations

105°C. At the first measurement of experiment 6, the pump of the test system was defected. To avoid bias, this measurement was not used for calculations. This measured weight was used as initial weight for the subsequent measurements.

105°C. At the fourth measurement of experiment 6, all cells were slightly contaminated. Therefore, the cell was meticulously cleaned and weighed. This weight was used as initial weight for the subsequent measurements. To avoid bias, this measurement was not used for calculations.

120°C. At the second measurement of experiment 7, all cells were slightly contaminated. Therefore, the cells were meticulously cleaned and weighed. This weight was used as initial weight for the subsequent measurements. To avoid bias, this measurement was not used for calculations.

135°C. At the second measurement of experiment 8, all cells were slightly contaminated. Therefore, the cells were meticulously cleaned and weighed. This weight was used as initial weight for the subsequent measurements. To avoid bias, this measurement was not used for calculations.

135°C. At the third measurement of experiment 8, cell 2 and 4 were slightly contaminated. Therefore, the cells were meticulously cleaned and weighed. This weight was used as initial weight for the subsequent measurements. To avoid bias, this measurement was not used for calculations.

Results of the molecular mass of 468 g/mol

The measured values for temperature and vapour pressure were evaluated as follows:

 Parameter  T [°C]  T [K]  p [Pa]  1/T [1/K]  log p [log Pa]

 Values

 105.0

 378.2

 3.94 x 10-3

 2.6441 x 10-3

 -2.4043

 120.0

 393.2

 6.42 x 10-3

 2.5432 x 10-3

 -2.1928

 135.0

 408.2

 1.12 x 10-2

 2.4498 x 10-3

 -1.9503

A graph with log p vs. 1/T was plotted. Since the values were correlated by a linear relation, the data could be fitted by linear regression. y = -2333.1 x + 3.757 with r²= 0.9962.

For the test substance, the following vapour pressures at 20 °C and at 25 °C were calculated from the regression equation:

Vapour pressure at 20 °C: 6.28 x 10-05 Pa

Vapour pressure at 25 °C: 8.54 x 10-05Pa

Results of the molecular mass of 860 g/mol

The measured values for temperature and vapour pressure were evaluated as follows:

 Parameter  T [°C]  T [K]  p [Pa]  1/T [1/K]  log p [log Pa]

 Values

 105.0

 378.2

 2.91 x 10-3

 2.6441 x 10-3

 -2.5364

 120.0

 393.2

 4.73 x 10-3

 2.5432 x 10-3

 -2.3249

 135.0

 408.2

8.27 x 10 -3

 2.4498 x 10-3

 -2.0824

A graph with log p vs. 1/T was plotted. Since the values were correlated by a linear relation, the data could be fitted by linear regression. y = -2333.1 x + 3.6248 with r²= 0.9962.

For the test substance, the following vapour pressures at 20 °C and at 25 °C were calculated from the regression equation:

Vapour pressure at 20 °C: 6.64 x 10-05 Pa

Vapour pressure at 25 °C: 6.30 x 10 -05 Pa

The molecular weight range is for the whole substance, therefore the whole substance has a range for the vapour pressure.

Conclusions:
Vapour pressure of test item at 20 °C: >= 6.28E-5 Pa - <= 6.64E-5 Pa
Vapour pressure of test item at 25 °C: >= 6.30E-5 Pa - <= 8.54E-5 Pa
Executive summary:

Vapour pressure of the test item was determined using Vapor Pressure Analyzer (Knudsen Effusion Method) following internationally accepted guidelines (OECD 104, EU Method A.4) in a non-GLP study.

The vapour pressure was measured in the temperature range of 30 to 150 °C. For the evaluation the vapour pressure values in the range of 105 to 135 °C were used.

The following results were obtained:

Vapour pressure of test item at 20 °C: >= 6.28 x 10 -5 Pa - <= 6.64 x 10 -5 Pa

Vapour pressure of test item at 25 °C: >= 6.30 x 10 -5 Pa - <= 8.54 x 10 -5 Pa

The molecular weight range is for the whole substance, therefore the whole substance has a range for the vapour pressure.

Description of key information

Vapour pressure of the test item was determined using Vapor Pressure Analyzer (Knudsen Effusion Method) following internationally accepted guidelines (OECD 104, EU Method A.4) in a non-GLP study.

The vapour pressure was measured in the temperature range of 30 to 150 °C. For the evaluation the vapour pressure values in the range of 105 to 135 °C were used.

The following results were obtained:

Vapour pressure of test item at 20 °C: >= 6.28 x 10-5 Pa - <= 6.64 x 10-5 Pa

Vapour pressure of test item at 25 °C: >= 6.30 x 10 -5 Pa - <= 8.54 x 10-5 Pa

The molecular weight range is for the whole substance, therefore the whole substance has a range for the vapour pressure.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information

The substance has based on its composition different constituents and therefore a range in the molecular weight. The vapour pressure is calculated for the upper and lower limit of the range. The value indicated as key value for the chemical safety assessment is the highest determined vapour pressure for the substance and regarded as worst-case scenario.