Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 812-029-3 | CAS number: 116713-40-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
The test item is not considered to be irritating to skin based on the results of the OECD Guideline study 439.
The test item is not considered to be irritating to eye based on the results of the OECD Guideline study 437.
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Apr 04 - Jun 06, 2019
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
- Version / remarks:
- Commission Regulation (EU) No. 640/2012 amending, for the purpose of its adaption to technical progress, Regulations (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006 of the European Parliament and the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Version / remarks:
- July 28, 2015
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Skinethic skin irritation test -42bis Standard operating procedure (SOP) 2009
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- TREATMENT OF TEST MATERIAL PRIOR TO TESTING
No pre-treatment ;The test item was applied neat to the tissues. - Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- foreskin from a single donor
- Justification for test system used:
- standard model
- Vehicle:
- unchanged (no vehicle)
- Remarks:
- No vehicle used in this study; The test item was applied neat to the tissues.
- Details on test system:
- CELL CULTURE
- Supplier: EpiSkin/SkinEthic Laboratories, Lyon, France)
- Source: human keratinocytes cultured on a polycarbonate filter in conditions which permit their terminal differentiation
- Format: 24 well plate
- Batch: 19-RHE-059
- Expires: April 22, 2019
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment: room temperature
- Temperature of post-treatment incubation: 37°C
REMOVAL OF THE TEST MATERIAL AND CONTROL
After the end of the treatment interval, the residual test item was removed immediately by gently rinsing with a minimum volume of 25 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the inserts and blotting the bottom with blotting paper.
DYE BINDING METHOD
- Dye used in the dye-binding assay: MTT
- Spectrophotometer:ELx800, BioTek Instruments GmbH, Bad Friedrichshall, Germany at 570 nm - Control samples:
- yes, concurrent negative control
- Amount/concentration applied:
- TEST MATERIAL: 16 mg of solid test material
NEGATIVE CONTROL: 16 µL (Dulbecco`s Phosphate-Buffered Saline)
POSITIVE CONTROL: 16 µL (5% aqueous solution of sodium dodecyl sulfate in deionised water) - Duration of treatment / exposure:
- 42 min (± 1 minute)
- Duration of post-treatment incubation (if applicable):
- 42 hours (± 1 hour)
- Number of replicates:
- 3
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Experiment 1 / Run 1
- Value:
- 106.7
- Vehicle controls validity:
- not applicable
- Remarks:
- The test item was applied neat to the tissues
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: none
- Colour interference with MTT: none
ACCEPTANCE OF RESULTS:
Acceptability of the Quality Control Data of the Skin Model with Reference to Historical Batch Data:
Acceptance Criterion Result
Negative control OD ≥ 0.8 and ≤ 3.0 1.703 to 1.814
Acceptability of the Positive and Negative Control stated by Episkin/SkinEthic Laboratories:
Acceptance Criterion Result
Mean OD negative control ≥ 1.2 1.769
Mean viability positive control < 40% 1.4%
SD of group-mean value ≤ 18% 14.3% (positive control)
3.3% (negative control)
Acceptability of the Positive and Negative Control based on Historical Data of the Testing Laboratory:
Acceptance Criterion Result
Mean OD negative control ≥ 1.417 1.769
Mean viability positive control ≤ 2.78% 1.4%
Test Item Data Acceptance Criteria:
Acceptance Criterion Result
SD of group-mean value ≤ 18% 3.0%
The study met all acceptance criteria. - Interpretation of results:
- GHS criteria not met
- Remarks:
- UN GHS: No Caterory (according to OECD TG 439)
- Conclusions:
- This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439. Under the conditions of the present study, the test item is not considered to possess an irritant potential to skin (UN GHS: No Category).
- Executive summary:
Objective
The objective of the present study was to investigate the potential of the test item to induce skin irritation in anin vitrohuman skin model.
Study Design
The test item was applied topically to a human reconstructed skin model followed by determination of the cell viability. Cell viability was determined by enzymatic conversion of vital dye MTT into a blue formazan salt and measurement of the formazan salt after extraction from tissues. The percent reduction of cell viability in comparison to untreated negative controls was used to predict the skin irritation potential.
Triplicates of the human skin RHE-model were treated with the test item, the negative or the positive control for 42 minutes (± 1 minute). 16 µL of either the negative control (DPBS-buffer) or the positive control (5% aqueous solution of sodium dodecyl sulfate) were applied to the tissues. Before application of 16 mg of the solid test item, 10 µL of deionised water was spread to the epidermis surface to improve the contact between the test item and the epidermis.
Results
All acceptability criteria after treatment with the negative control (DPBS-buffer) and the positive control (5% aqueous solution of sodium dodecyl sulfate) were met.
Following treatment with the test item, the tissue viability was 106.7% and, thus, higher than 50%, i.e. according to OECD 439 the test item is considered as non-irritant to skin (UN GHS: No Category).
Conclusion
Under the conditions of the present study, the test item is not considered to possess an irritant potential to skin (UN GHS: No Category).
Reference
Group | Time / [min] | Mean OD | Mean Relative viability / [%] |
Negative Control | 42 | 1.769 | 100 |
Positive Control | 42 | 0.025 |
1.4 |
Test Material |
42 |
1.888 |
106.7 |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Apr 26 - Aug 21, 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- other: OCD 437
- Version / remarks:
- 09 October 2017
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
- Version / remarks:
- Commission Regulation (EU) No. 1152/2010 amending, for the purpose of its adaption to technical progress, Regulation (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006 of the European Parliament and the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- PREPARATION OF THE TEST MATERIAL
The test item was prepared as a 20% (w/v) suspension in a 0.9% sodium chloride solution. The stability in the vehicle was not investigated. The test item preparation was administered within <1 hour after preparation. - Vehicle:
- physiological saline
- Controls:
- yes, concurrent vehicle
- yes, concurrent positive control
- Amount / concentration applied:
- Preparation
The test item was prepared as a 20% (w/v) solution in a 0.9% sodium chloride solution. The stability in the vehicle was not investigated. The test item preparation was administered within <1 hour after preparation.
TEST MATERIAL: 750 µL (i.e. 150mg/750µL)
NEGATIVE / VEHICLE CONTROL: 750 µL
Designation: 0.9% sodium chloride solution
Supplier: B. Braun Melsungen AG, Germany
Batch: 118163013
Storage: 2 to 8°C
Released until: Mar 2021
POSITIVE CONTROL: 750 µL
Designation: Art. 814223
Synonym: Imidazole
Supplier: Merck KGaA, Germany
Batch: S5798623
Content (GC) 99.8% (a/a)
Storage: At room temperature
Released until: April 30, 2023
Imidazole was dissolved with 0.9% sodium chloride solution to a concentration of 20% (w/v) - Duration of treatment / exposure:
- 240 minutes
- Number of animals or in vitro replicates:
- in vitro: triplicate design
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Run 1 / Experiment 1
- Value:
- 0
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- ACCEPTANCE OF RESULTS:
After treatment with the negative control (0.9% sodium chloride solution) the calculated IVIS was 1.7 and, thus, within three standard deviations of the current historical mean of the negative control (IVIS: -1.4 – 3.0). After treatment with the positive control (20% Imidazole) the calculated IVIS was 107.9 and, thus, also within two standard deviations of the current historical mean of the positive control (IVIS: 83.3 – 132.0). Therefore, the study fulfilled the acceptance criteria.
The resulting classification of the test item in this study is unequivocal and no borderline results were obtained. Therefore, a single testing run composed of three corneas per group was considered sufficient. - Interpretation of results:
- GHS criteria not met
- Conclusions:
- Under the conditions of the present study, did not show an eye hazard potential. The test item is not requiring classification for eye irritation or serious eye damage (UN GHS: No Category).
- Executive summary:
The objective of the present study was to examine the potential of the test item to induce serious eye damage in the BCOP assay. The BCOP assay with isolated fresh bovine corneas is an accepted in vitro model for ocular hazard assessment.
To determine the eye hazard potential the induced opacity and increased permeability was investigated in isolated bovine corneas after exposure to the test item as a 20% (w/v) solution in a 0.9% sodium chloride solution. As negative control 0.9% sodium chloride solution and as positive control 20% (w/v) Imidazole was used.
Three corneas were used per group (negative control, positive control or test item group).
After a first opacity measurement of the untreated bovine corneas, 750 µL of the dissolved test item, positive or negative control were applied on the corneas and incubated for 240 minutes. After the incubation phase the test item, the positive, and the negative control were rinsed from the corneas and the opacity was measured again.
After the opacity measurements, the permeability of the corneas was determined by application of a fluorescein solution for 90 minutes. The amount of fluorescein solution that crossed the cornea was measured spectrophotometrically.
The opacity and permeability assessments were combined to determine an In Vitro Irritancy Score (IVIS).
After treatment with the negative control (0.9% sodium chloride solution) the calculated IVIS was 1.7 (study acceptance criteria range: -1.4 – 3.0). Treatment with the positive control (20% Imidazole) revealed an IVIS of 107.9 (study acceptance criteria range: 83.3 – 132.0). Therefore, the study fulfilled the acceptance criteria.
The IVIS obtained after treatment with the test material was 0.0 and, thus, lower than 3, i.e. according to OECD 437 the test item is not requiring classification for eye irritation or serious eye damage (UN GHS: No Category).
Under the conditions of the present study, did not show an eye hazard potential. The test item is not requiring classification for eye irritation or serious eye damage (UN GHS: No Category).
Reference
Opacity |
Permeability |
IVIS |
||||
per cornea |
per group (mean value) |
Standard deviation |
||||
Negative Control |
0.9 % sodium chloride solution |
0.4 |
0.003 |
0.445 |
1.7 |
1.2 |
2.0 |
0.002 |
2.030 |
||||
2.7 |
0.000 |
2.700 |
||||
Positive Control |
Imidazole (20 %) |
73.0 |
1.429 |
94.435 |
107.9 |
12.5 |
69.0 |
2.745 |
110.175 |
||||
71.4 |
3.182 |
119.130 |
||||
Test Item |
- |
1.6 |
0.003 |
1.645 |
0.0 |
1.5 |
-1.2 |
-0.001 |
-1.215 |
||||
-0.6 |
0.002 |
-0.570 |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Justification for classification or non-classification
The test item is neither classified for skin irritation/corrosion nor for eye irritation/corrosion according to Regulation (EC) No 1272/2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.