Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 817-766-4 | CAS number: 91891-42-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flammability
Administrative data
- Endpoint:
- flammable liquids: obsolete as covered by section 'Flash point'
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is a liquid
Cross-referenceopen allclose all
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 05 Oct 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Deviations:
- no
- GLP compliance:
- no
- Type of method:
- closed cup
- Flash point apparatus:
- Pensky-Martens apparatus
- Key result
- Atm. press.:
- 990 hPa
- Remarks on result:
- other: Did not flash prior to boilingat 58 °C, however, flame enlargement and a color change of the flame were observed.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- MA-3 did not flash prior to boiling at 58 °C by Penksy-Martens closed cup test (EU method A.9). Flame enhancement was observed.
- Executive summary:
No flash-point could be determined using the Pensky-Martens closed cup method. Flame enlarged and flickered with a turquoise hue and promptly extinguished upon pilot flame application at 22 °C. The study was conducted in accordance with EU method A.9; therefore the study is considered reliable without restrictions and is suitable for Classification & Labeling and Risk Assessment.
Flame enlarged and flickered with a turquoise hue and promptly extinguished upon pilot flame application. This was first observed at 22°C. Boiled at 58°C.
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- auto-ignition temperature (liquids)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 02 - 18 Oct 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
- Deviations:
- no
- GLP compliance:
- yes
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: MA-3-HO-ANL 1600356
- Expiration date of the lot/batch: 31 Aug 2020
- Purity test date: 05 Feb 2018
- Purity: 96.9%
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature container flushed with nitrogen
- Stability under test conditions: Yes - Key result
- Auto-ignition temperature:
- 605 °C
- Atm. press.:
- 1 014 hPa
- Conclusions:
- The autoignition temperature of MA-3 is 605 °C at 1014 hPa, EU method A.15
- Executive summary:
The lowest observed autoignition temperature was 609 °C. This value was rounded down to 605 °C per guideline. The study was conducted in accordance with EU Method A.15 and was GLP compliant, therefore the study is considered reliable without restrictions.
Data source
Materials and methods
Results and discussion
Applicant's summary and conclusion
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.