First-aid measures

General advice

Remove from exposure, lie down.
Take off immediately all contaminated clothing.
Victim to lie down in the recovery position, cover and keep him warm.
First Aid responders should pay attention to self-protection and use the recommended protective clothing

If inhaled
Keep patient calm, remove to fresh air, seek medical attention.

In case of skin contact
Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist.

In case of eye contact
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist.

If swallowed
Rinse mouth immediately and then drink plenty of water, seek medical attention.

Most important symptoms and effects, both acute and delayed
No information available

Indication of any immediate medical attention and special treatment needed
Treatment: Symptomatic treatment (decontamination, vital functions).

Fire-fighting measures

Extinguishing media

Suitable extinguishing media
Use extinguishing measures that are appropriate to local cir-cumstances and the surrounding environment.
Water
Foam
Carbon dioxide (CO2)
Dry chemical

Special hazards arising from the substance or mixture
Specific hazards during fire fighting
In case of fire and/or explosion do not breathe fumes. Can be released in case of fire: Carbon oxides

Advice for firefighters
Special protective equipment for firefighters
In case of fire and/or explosion do not breathe fumes. Self-contained breathing apparatus (EN 133)

Further information
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Personal precautions
Wear personal protective equipment. Avoid dust formation. Remove all sources of ignition. Ensure adequate ventilation.

Environmental precautions
Do not flush into surface water or sanitary sewer system.

Methods for cleaning up
Cleaning operations should be carried out only while wearing breathing apparatus.
Clean-up methods - large spillage
Dampen, pick up mechanically and dispose of.
Clean-up methods - small spillage
Use approved industrial vacuum cleaner for removal.
Keep in suitable, closed containers for disposal.
Avoid raising dust.

Handling and storage

Precautions for safe handling
Advice on safe handling
Ensure thorough ventilation of stores and work areas.
Breathing must be protected when large quantities are de-canted without local exhaust ventilation.
Do not open until use.
Protect from moisture.

Advice on protection against fire and explosion
Keep away from heat and sources of ignition. Take precautionary measures against static discharges. Avoid creating dust.

Hygiene measures
General industrial hygiene practice. Wash hands and face before breaks and immediately after handling the product. Keep working clothes separately.

Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers
Jointless smooth floor Protect from heat and direct sunlight. Keep containers tightly closed in a cool, well-ventilated place.

Advice on common storage
Keep away from food, drink and animal feedingstuffs. Advice on Segregation

Storage class (TRGS 510) : 11, Combustible Solids

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not regulated as a dangerous good
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not regulated as a dangerous good
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not regulated as a dangerous good
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not regulated as a dangerous good
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters
Contains no substances with occupational exposure limit values.

Exposure controls
Engineering measures
Use with local exhaust ventilation.

Personal protective equipment
Eye protection : Safety glasses with side-shields.

Hand protection
Material : Nitrile rubber
Break through time : 480 min
Glove thickness : 0,43 mm
Directive : Protective gloves against chemicals and micro-organisms
Protective index : Class 6

Skin and body protection : Laboratory: laboratory coat; factory: disposable Overall.

Respiratory protection : Respirator must be worn if exposed to dust.
half mask (EN 140)
particle filter P2

Protective measures: Avoid contact with skin, eyes and clothing. Do not breathe dust. Handle in accordance with good industrial hygiene and safety practice.

Stability and reactivity

Reactivity
No dangerous reaction known under conditions of normal use.

Chemical stability
No decomposition if stored and applied as directed.

Possibility of hazardous reactions
Hazardous reactions : Dust can form an explosive mixture with air.

Conditions to avoid
Conditions to avoid : No data available

Incompatible materials
Materials to avoid : No data available

Hazardous decomposition products
No data available




Disposal considerations

Waste treatment methods
Product : Dispose of in accordance with local regulations.