Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29/06/09 - 23/07/09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed to current accepted guidelines.
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no

During the preliminary screening test, the pile failed to ignite during the two minutes that the Bunsen flame was applied. The negative results of the screening test negated the need to perform the main test.

 

Table 1: Moisture Content of the Test Material

 

 

Determination A

Determination B

a) Mass of loss bottle (g)

20.7029

20.5721

b) Mass of loss bottle and test material (g)

21.7072

21.5812

c) Mass of loss bottle and test material after drying

21.7044

21.5783

Moisture content (% w/w)

0.279

0.287

Mean moisture content (% w/w)

0.283

 

Interpretation of results:
non flammable
Conclusions:
Manganese sulphide is non-flammable.
Executive summary:

The flammability of the test material was assessed according to EU Method A.10.

During the preliminary screening test, the pile failed to ignite during the two minutes that the Bunsen flame was applied. The negative results of the screening test negated the need to perform the main test.

Under the conditions of the study the test material is not flammable.

Description of key information

Manganese sulphide is non-flammable.

In accordance with section 1.5 of REACH Annex XI, the study does not need to be performed as based on chemical structure pyrophoric properties are not to be expected.

 

In accordance with section 1.5 of REACH Annex XI, the study does not need to be performed as based on chemical structure water reactivity is not to be expected.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test material was assessed according to EU Method A.10.

During the preliminary screening test, the pile failed to ignite during the two minutes that the Bunsen flame was applied. The negative results of the screening test negated the need to perform the main test.

Under the conditions of the study the test material is not flammable.

Justification for classification or non-classification