Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 Sept to 23 Sept 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: UN Test N.4 (Recommendation on the Transport of Dangerous Goods: Manual of Tests and Criteria, 6th edition, New York and Geneva, 2015, Appendix 6, Screening procedures, Division 4.2: Substances which may be liable ot spontaneous combustion
Qualifier:
according to guideline
Guideline:
other: VDI 2263 (1990), sheet 1, Grewer oven
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium für Umwelt, Energie, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Key result
Remarks on result:
no self-ignition observed up to the melting point

Self-ignition in the Grewer oven

In the investigation of self-ignition in the Grewer oven for the pure test item an endothermic process was detected starting at a temperature of approx. 100 °C, which can be assigned to melting of the test item (melting range 109- 111 °C according SDS). No further thermal effects could be observed up to the maximum test temperature of 400 °C. After the test the wire basket of the pure test item was empty.

For the test item in mixture with Kieselguhr also an endothermic effect was detected starting at a temperature of approx. 100 °C, which can be assigned to the melting of the test item. No further thermal effects could be observed up to the maximum test temperature of 400 °C.

Table: Results of the screening test for self-ignition in the Grewer oven

Experiment

Onset self-ignition / °C

Maximum temperature / °C

Pure test item

---

---

Test item in mixture with Kieselguhr (1:1)

---

---

 

Final Results / Classification

The pure test item dehydroacetic acid indicated no self-ignition at atmospheric pressure before reaching its melting point at a temperature of approx. 100 °C. Due to this, it can be assumed that the UN test N.4 using the 25 mm cube sample at 140 °C is negative.

On the basis of the results of the tests on the self-ignition in the Grewer oven the test item is classified as non-self-heating substance (neither according to UN Transport regulation nor according to GHS / CLP).

Description of key information

The substance dehydroacetic acid shows no self-heating up to the temperature of melting point (UN N.4, Grewer oven).

Key value for chemical safety assessment

Additional information