Administrative data

First-aid measures

General advice       

Remove and wash contaminated clothing before re-use.

In the case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

Show this safety data sheet to the doctor in attendance.

First aider needs to protect himself.

If inhaled       

IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing.

Call a physician immediately.

Show this safety data sheet to the doctor in attendance.

No artificial respiration, mouth-to-mouth or mouth to nose. Use suitable instruments/apparatus.

In case of skin contact       

Wash off immediately with plenty of water.

Call a physician immediately.

In case of eye contact       

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

If swallowed       

In the case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

Show this safety data sheet to the doctor in attendance.

Prevent vomiting if possible.

Immediately give large quantities of water to drink.

Ingest activated charcoal.

Notes to physician       

Treat symptomatically.

Fire-fighting measures

Suitable extinguishing media       

Carbon dioxide (CO2)

Foam

Water spray

Dry powder

Special exposure hazards arising from the substance or preparation itself, its combustion products, or released gases       

Gaseous hydrogen chloride (HCl).

Special protective equipment for firefighting       

Personal protection through wearing a tightly closed chemical protection suit and a self-contained breathing apparatus.

Additional information on firefighting       

Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions       

Use personal protective equipment.

For personal protection see section Exposure controls / personal protection.

Environmental precautions       

Do not flush into surface water or sanitary sewer system.

Avoid subsoil penetration.

Methods for cleaning up       

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Pick up and transfer to properly labelled containers..

Dispose of as special waste in compliance with local and national regulations.

Clean contaminated floors and objects thoroughly while observing environmental regulations.

Handling and storage

Only skilled and frequently trained personnel handle the product.

Advice on safe handling: Provide good ventilation of working area (local exhaust ventilation if necessary).

Advice on protection against fire and explosion: Take precautions against accumulation of electrostatic charge

Requirements for storage rooms and vessels: Keep only in the original container

Advice on storage compatibility: Do not store or transport together with foodstuffs

Further information on storage conditions: Keep container tightly closed in a cool, well-ventilated place

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
1181
Shipping information
Proper shipping name and description:
ETHYL CHLOROACETATE
Chemical name:
ETHYL CHLOROACETATE
Language:
English
Labels:
6.1 + 3
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
1181
Shipping information
Proper shipping name and description:
ETHYL CHLOROACETATE
Chemical name:
ETHYL CHLOROACETATE
Labels:
6.1 + 3
Marine pollutant
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
1181
Shipping information
Proper shipping name and description:
Ethyl chloroacetate
Chemical name:
Ethyl chloroacetate
Labels:
6.1 - Toxic Substance; 3 - Flammable Liquid
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Respiratory protection       

In case of inadequate ventilation wear respiratory protection.

Respirator with a gas filter ( Recommended Filter type: A)

Hand protection       

Impervious butyl rubber gloves

Material thickness:       0,7 mm

Break through time:       > 480 min

Reference substance:       Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).

Eye protection       

Tightly fitting safety goggles

Skin and body protection       

Wear suitable protective equipment.

General protective and hygiene measures       

Handle in accordance with good industrial hygiene and safety practice. When using, do not eat, drink or smoke. Avoid contact with skin, eyes and clothing. Keep away from food, drink and animal feedingstuffs.

Wash hands before breaks and at the end of workday.

Do not breathe vapours or spray mist.

Engineering measures       

Ensure adequate ventilation, especially in confined areas.

Apply technical measures to comply with the occupational exposure limits.

We declare that the substance is manufactured under strictly controlled conditions during its whole lifecycle. Furthermore, we have received confirmation from the user that the synthesis of other substance from this intermediate takes place under strictly controlled conditions during its whole lifecycle as described under Article 18(4) and Section 2.1 of the Guidance for Intermediates.

Effectiveness:

Prevention of exposure since the substance is rigorously contained by technical means during its whole lifecycle and procedural and control technologies are used to minimise emission and any resulting exposure as described under Article 18(4).

Occupational Exposure Limit

Type of limit MAK (DE) 1 ml/m3

Stability and reactivity

Hazardous decomposition products       

Gaseous hydrogen chloride (HCl), chloroacetic acid.

Hazardous reactions       

No dangerous reaction known under conditions of normal use.

Materials to avoid       

Incompatible with strong acids and bases.

Oxidizing agents

Disposal considerations

Disposal considerations       

Dispose of in accordance with the European Directives on waste and hazardous waste. Waste codes should be assigned by the user, preferably in discussion with the waste disposal authorities.

Can be incinerated, when in compliance with local regulations.

Uncleaned empty packaging       