Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test conducted according to Sieving method and ECHA Guidance.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Sieving method
Deviations:
not specified
Principles of method if other than guideline:
Sieving method is measuring devices used to determine the size and size distribution of particles in a material sample using wire mesh of different opening to separate particles of different sizes. Test sieving usually consist of wire mesh held in a frame which is round and made from stainless steel. A typical sieve analysis involves a nested column of sieves with wire mesh cloth (screen).

A representative weighed sample is poured into the top sieve which has the largest screen openings. Each lower sieve in the column has smaller opening than the one above. After shaking for some fixed amount of time, is complete the material on each sieve is weighed. The weight of the sample of each sieve is then divided by the total weight to give a percentage retained on each sieve.

The size of the average particles on each sieve then being analysis to get the cut-point or specific size range captured on screen.
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Constituent 1
Reference substance name:
1,3,5-Triazine-2,4,6-triamine, N2,N2'-1,2-ethanediylbis[N2-[3-[[4,6-bis[butyl(1,2,2,6,6- pentamethyl-4-piperidinyl)amino]-1,3,5-triazin-2-yl]amino]propyl]-N4,N6-dibutyl-N4,N6-bis(1,2,2,6,6-pentamethyl-4-piperidinyl)-
IUPAC Name:
1,3,5-Triazine-2,4,6-triamine, N2,N2'-1,2-ethanediylbis[N2-[3-[[4,6-bis[butyl(1,2,2,6,6- pentamethyl-4-piperidinyl)amino]-1,3,5-triazin-2-yl]amino]propyl]-N4,N6-dibutyl-N4,N6-bis(1,2,2,6,6-pentamethyl-4-piperidinyl)-
Constituent 2
Chemical structure
Reference substance name:
N,N',N'',N'''-tetrakis(4,6-bis(butyl-(N-methyl-2,2,6,6-tetramethylpiperidin-4-yl)amino)triazin-2-yl)-4,7-diazadecane-1,10-diamine
EC Number:
401-990-0
EC Name:
N,N',N'',N'''-tetrakis(4,6-bis(butyl-(N-methyl-2,2,6,6-tetramethylpiperidin-4-yl)amino)triazin-2-yl)-4,7-diazadecane-1,10-diamine
Cas Number:
106990-43-6
Molecular formula:
C132H250N32
IUPAC Name:
N2-[2-({4,6-bis[butyl(1,2,2,6,6-pentamethylpiperidin-4-yl)amino]-1,3,5-triazin-2-yl}[3-({4,6-bis[butyl(1,2,2,6,6-pentamethylpiperidin-4-yl)amino]-1,3,5-triazin-2-yl}amino)propyl]amino)ethyl]-N2-[3-({4,6-bis[butyl(1,2,2,6,6-pentamethylpiperidin-4-yl)amino]-1,3,5-triazin-2-yl}amino)propyl]-N4,N6-dibutyl-N4,N6-bis(1,2,2,6,6-pentamethylpiperidin-4-yl)-1,3,5-triazine-2,4,6-triamine
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Particle size
Percentile:
D50
Mean:
1 420 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 2 000 µm
Distribution:
23.38 %
No.:
#2
Size:
> 840 - < 2 000 µm
Distribution:
66.22 %
No.:
#3
Size:
< 840 µm
Distribution:
10.4 %

Applicant's summary and conclusion

Conclusions:
Mass median diameter: 1420 μm
- 23.38 % greater than 2000 microns
- 66.22 % greater than 840 microns but less than 2000 microns
- 10.4 % smaller than 840 microns