Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2002
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The test was carried out according to an Spanish standard by an accredited test laboratory, but not GLP compliant. Experimental measurement results are considered reliable.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report date:
2002

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: UNE 31-016-94
Qualifier:
according to guideline
Guideline:
other: UNE 31-018-94
GLP compliance:
not specified

Test material

Constituent 1
Reference substance name:
Isochroman
IUPAC Name:
Isochroman
Test material form:
solid: particulate/powder
Remarks:
migrated information: particulates
Details on test material:
- Name of test material (as cited in study report):ARDF-26 Fase N°6.1
- Molecular formula (if other than submission substance): C12 H12 O4
- Molecular weight (if other than submission substance):120.23
-- Physical state: white dull coloured product, mixture of fine and coarse particles
Humidity : 17.9 %
granulomtry: d (0.1):3.9 µm; d(0.5):12.4; d(0.9): 82.1

Results and discussion

Small-scale preliminary tests
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Remarks:
No total nor partial detonation produced

Any other information on results incl. tables

Sample PYA-6 of product named ISOCHROMAN does not produce detonation when subjected to shock sensitivity of explosives test and does not produce either any reaction in the rubbing or friction sensitivity of explosives test.Thus an intrinsically explosive behaviour can be discarded.

Applicant's summary and conclusion

Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions: