Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Principles of method if other than guideline:
Purity of the test substance: 99.8 %
Batch No.: 30869
GLP compliance:
yes (incl. QA statement)
Type of method:
oscillating densitimeter

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of bis(2-ethylhexyl) adipate and cyclohexyl 2-ethylhexyl adipate and dicyclohexyl adipate
EC Number:
948-946-1
Molecular formula:
C20H36O4, C18H30O4, C22H42O4
IUPAC Name:
Reaction mass of bis(2-ethylhexyl) adipate and cyclohexyl 2-ethylhexyl adipate and dicyclohexyl adipate
Test material form:
liquid
Specific details on test material used for the study:
Purity of the test substance: 99.8 %
Batch No.: 30869

Results and discussion

Density
Key result
Type:
relative density
Density:
0.98 other: no unit
Temp.:
20 °C
Remarks on result:
other: D20/4

Any other information on results incl. tables

Results in detail:

  1st determination   3rd determination
 density of thr test item (g/ml) 0.98017  0.98018 
density of the test item mean (g(ml)      0.9802
relative density D20/4  0.98020  0.98020 
relative density D20/4 mean      0.9802

The measurement of the 2nd determination was discarded because of an air bubble in the measuring tube.

Applicant's summary and conclusion