Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The vapor pressure could not be determined.

Key value for chemical safety assessment

Additional information

The measurements conducted at approximately 100 °C show a rapidly decreasing vapor pressure which indicates a thermally

caused change of the test item. For the measurements conducted at 56.6 and below a new

sample of the test item was used and the observation of the earlier measurements at higher temperatures could be reproduced

which indicates that the thermally caused change of the test item recorded at temperatures of appr. 100°C also occurs at

temperature of appr. 56.6 °C. Therefore, the vc;1por pressure could not be determined.

At 20 °C the detection limit is reached.