Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017.8.1 - 2017.9.13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Version / remarks:
27.July 1995
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
distillation method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Miramer S512 (Reaction mass of tris(2-hydroxyethyl)isocyanurate triacrylate (THEICTA) and tris(2-hydroxyethyl)isocyanurate diacrylate (THEICDA)), Lot No.: 170604470
- Expiration date of the lot/batch: 2018-06-07
- Purity test date: 2017-06-08

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: not specified

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: sample for testing used as supplied without any further treatment.
Key result
Decomposition:
no
Remarks on result:
not determinable
Remarks:
Not distilled at the max. Temperature 250 degree Celcius
Conclusions:
The boiling point of Miramer S512 could not be determined at 101.3 kPa under the given methodology.
Executive summary:

The boiling point was determined according to OECD TG 103 under ISO 17025 standards Boiling point not determined at temperatures up to 250 degree Celcius (101.3 kPa). Conclusively, boiling point of Miramer S512 was not determined at 101.3 kPa.

Description of key information

Boiling point not determined at temperatures until 250 degree Celcius (101.3 kPa). Conclusively, boiling point of Miramer S512 was not determined at 101.3 kPa

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
250 °C

Additional information

Boiling point not determined at temperatures until 250 degree Celcius (101.3 kPa). Conclusively, boiling point of Miramer S512 was not determined at 101.3 kPa