Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes
Type of method:
static method

Test material

Constituent 1
Chemical structure
Reference substance name:
Bis(1,3-dimethylbutyl) maleate
EC Number:
203-304-3
EC Name:
Bis(1,3-dimethylbutyl) maleate
Cas Number:
105-52-2
Molecular formula:
C16H28O4
IUPAC Name:
bis(1,3-dimethylbutyl) maleate

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
5.5 Pa
Remarks on result:
other: mean of runs 1 & 2

Any other information on results incl. tables

 Temp / °C  Temp / K  P / mbar  **P / Pa
          Run 1
*20   293.15  0.06  6
 20.8  293.95  0.0632  6.32
 30.0  303.15  0.1321  13.21
40.0  313.15  0.2273  22.73
 50.0  323.15  0.468  46.8
 60.2  333.35  0.8124  81.24
          Run 2
 *20  293.15 0.05  5
 20.0  293.15  0.0482  4.82
 30.0  303.15  0.0987  9.87
 40.0  313.15  0.212  21.2
 50.0 323.15  0.4553  45.53
 60.0 333.15  0.9375  93.75

* - Determined by extrapolation ** - Calculated

Comment.

Run 1:

A small amount of solid was observed at the bottom of the supplied sample. The sample was

shaken to give a consistent sample. Weight of flask + stirrer bar 38.55 gram, Weight of sample

20.03 gram. Weight of flask + sample + stirrer bar after testing 58.40 gram. Weight loss during

testing 0.18 grams, corresponds to a 0.9 % weight loss.

Run 2

Initial starting pressure 0.0018 mBar.

Applicant's summary and conclusion

Conclusions:
Result : 5.5 Pa at 20°C (mean of runs 1 & 2)
Executive summary:

Result : 5.5 Pa at 20°C (mean of runs 1 & 2)