Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18.09.2017 to 20.09.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
1995
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
2008
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab, Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main (Germany)
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
L-Alanine, N-coco acyl derivs., sodium salts
EC Number:
290-478-9
EC Name:
L-Alanine, N-coco acyl derivs., sodium salts
Cas Number:
90170-45-9
Molecular formula:
RHNNaO3
IUPAC Name:
L-Alanine, N-coco acyl derivs., sodium salts
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1, Kyobashi 1-chome, Chuo-ku, Tokyo 104-8315, Japan, Batch No.: 160325
- Expiration date of the lot/batch: 2020-03-25
- Purity test date: 2016-06-09

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: stored at ambient temperature

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
>= 130 - <= 148 °C
Atm. press.:
>= 1 003 - <= 1 004 hPa
Decomposition:
no

Any other information on results incl. tables

The evaluation of the data obtained by DSC measurements was performed using the software STARe.

Applicant's summary and conclusion

Conclusions:
The test item melts in the range from 130 to 148°C at atmospheric pressure.
Executive summary:

The melting point of the test item was investigated in a study conducted according OECD Guideline 102 (Melting point / Melting Range; 1995) and EU Method A.1 (Melting / Freezing Temperature; 2008) using DSC and capillary measurements. Based on DSC measurements, a melting point was determined in the range from 130 to 132°C at atmospheric pressure. To confirm the results obtained by DSC measurements additional measurements were performed using the capillary method. At a temperature of about 148°C the test item was completely molten. Taking into account the DSC and capillary measurements, the test item has a melting range from 130 to 148°C at atmospheric pressure.