Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
Pensky-Martens closed cup method
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93, Standard Test Method for Flash Point by Pensky-Martens Closed Cup
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point:
> 109.5 - < 110.5 °C
Atm. press.:
101.3 hPa
Conclusions:
The flash point of 6 -chlorohexan-1-ol determined by Pensky-Martens closed cup method
is 110.5 oC
Executive summary:

The flash point of 6 -chlorohexan-1-ol determined by Pensky-Martens closed cup method is 110.5 oC

Description of key information

The flash point of 6 -chlorohexan-1-ol determined by Pensky-Martens closed cup method is 110.5 C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
110.5 °C

Additional information