Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 June 2016 to 17 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
>= 99 - <= 124 °C
Atm. press.:
102 kPa
Decomposition:
no
Sublimation:
no
Remarks on result:
other: broad endotherms observed

RESULTS

- Thermograms and thermographic data for Determinations 1 and 2 are shown in Figures 1 and 2 (attached).

- Broad endotherms were observed at atmospheric pressure of 102 kPa and these were interpreted as melting ranges of 103 to 124 °C (Determination 1) and 99 to 124 °C (Determination 2).

Conclusions:
The melting/freezing point of the test item was determined to be 99 to 124 °C (372 to 397 K).
Executive summary:

GUIDELINE

The investigation was performed by differential scanning calorimetry using a method designed to be compatible with OECD 102 (27 July 1995) and Method A.1 Melting/Freezing Temperature of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The melting/freezing point of the test item was determined to be 99 to 124 °C (372 to 397 K).

Description of key information

The melting/freezing point of the test item was determined to be 99 to 124 °C (372 to 397 K) (OECD 102 and EU Method A.1).

Key value for chemical safety assessment

Additional information

The investigation was performed by differential scanning calorimetry using a method designed to be compatible with OECD 102 (27 July 1995) and EU Method A.1 Melting/Freezing Temperature of Commission Regulation (EC) No 440/2008 (30 May 2008).