Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Data waiving:
other justification
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid non flammable in air, e.g. no flash point up to 200°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27-05-2014 to 13-06-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
ASTM D6450-99. This method is correlated with the method ASTM D93
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
> 200 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: vapour pressure estimated; value not mentioned
Interpretation of results:
GHS criteria not met
Conclusions:
ASTM D6450-99. This method is correlated with the method ASTM D93
Executive summary:

The flash point of the test material was determined according to ASTM D6450-99 (method correlated with ASTM D93). The flash point of the test material was measured to be > 200 °C)

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion