Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 404-450-2 | CAS number: 118685-34-0 COBRATEC 435
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 16.05.1989- 25.05.1989
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- GLP compliance:
- yes
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source: Betz Laboratories Inc
- Purity test date: 82% and 91.4%
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: In the dark at room temperature
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: No
- Preliminary purification step (if any): No
- Final dilution of a dissolved solid, stock liquid or gel: No - Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- 0.65
- Temp.:
- 19 °C
- Remarks on result:
- other: pH not measured
- Remarks:
- Substance is a salt and the pH will not have a significant effect on the partition coefficient
- Conclusions:
- The partition coefficient (n-octanol/water) of Butyl benzotriazole sodium salt has been determined as:
lg Pow = 0.65 at 19°C ± 0.5°C - Executive summary:
The partition coefficient (n-octanol/water) of Butyl benzotriazole sodium salt has been determined as: lg Pow = 0.65 at 19°C ± 0.5°C according to EU Method A.8 (Partition Coefficient).
Reference
Analytical data: concentration Butyl benzotriazole sodium salt in n-octanol solution before partition.
Duplicate | Peak height | Original concentration (µg/ml) | Mean result (µg/ml) |
AB | 190176190227 | 2039.12039.6 | 2039.4 |
Analytical data: Organic phase analysis
Test | Peak height | Concentration test phase after partition (µg/ml) | Volume of test phase (ml) | Total µg in test phase after partition |
1A | 231000 | 1651.1 | 20 | 33021 |
1B | 229795 | 1642.5 | 20 | 32849 |
2A | 238872 | 1707.3 | 40 | 68292 |
2B | 236466 | 1690.1 | 40 | 67605 |
3A | 226901 | 1621.8 | 10 | 16218 |
3B | 226635 | 1619.9 | 10 | 16198 |
Calculation by SP4270 integrator using the data from the first calibration curve.
test | Peak height | Concentration test phase after partition (µg/ml) | Volume of test phase (ml) | Total µg in test phase after partition |
1A | 201052 | 431.13 | 20 | 8622.6 |
1B | 200335 | 429.60 | 20 | 8591.9 |
2A | 331577 | 710.91 | 20 | 14218 |
2B | 335036 | 718.32 | 20 | 14366 |
3A | 105045 | 225.34 | 20 | 4506.9 |
3B | 104997 | 225.24 | 20 | 4504.8 |
Calculated by SP4270 integrator using the data from the first calibration curve.
Calculation of partition coefficients
Test | Organic phase concentration | Aqueous phase concentration | Pow | Mean Pow for each test | Mean Pow for all determinations | log Pow |
1A | 1651.1 | 431.13 | 3.830 | 3.827) | 4.466 | 0.583 |
1B | 1642.5 | 429.60 | 3.823 | ) | 0.582 | |
2A | 1707.3 | 710.91 | 2.402 | 2.378) | 0.380 | |
2B | 1690.1 | 718.32 | 2.353 | ) | 0.372 | |
3A | 1621.8 | 225.34 | 7.197 | 7.195) | 0.857 | |
3B | 1619.9 | 225.24 | 7.192 | ) | 0.857 |
Description of key information
The partition coefficient (n-octanol/water) of butyl benzotriazole sodium salt has been determined as:
log Pow = 0.65 at 19°C ± 0.5°C
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 0.65
- at the temperature of:
- 19 °C
Additional information
Concentration of Butyl benzotriazole sodium salt in n-octanol test solution before partition.
The concentration of Butyl bezotriazole sodium salt in the n-octanol test solution before partition was determined as 2039.4 µg/ml.
Analytical data are given in Table 4 (attached report).
The concentration of Butyl benzotriazole sodium salt in the n-octanol test solution before partition, based on the mass of test substance used was 1968.05 µg/ml
Concentration of Butyl benzotriazole sodium salt in aqueous and organic test phases after partition.
analytical data are given in tables 5 and 6 (attached report)
Butyl benzotriazole sodium salt was not detected in the blank test phases. Results are not corrected for purity of test substance.
Calculation of partition coefficients
Data for the calculation of the partition coefficient of Butyl benzotriazole sodium salt are given in Table 7 (attached document)
the average value of the partition coefficient from all determinations was:
P= 4.466
log P: 0.650
Standard deviation of individual P values about their mean is: 2.211
The range of log P values was 0.485 log units- within the reapetability criteria of 0.6 log units required by Annnex V.
Typical chromatography are given in Figure1 -2 (attached document)
A repeat test was carried out to confirm the trend of varying partition coefficient with varying solvent ratio. The results of the repeat test agree very closely with the results of this test and hence only the results of the first test are reported here.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.