Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005-11-14 to 2005-12-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
31 July 1992
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
27 July 1995
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
column elution method
Key result
Water solubility:
0.05 mg/L
Temp.:
20 °C
pH:
6
Details on results:
At the plateau, the concentration of [14C] HAT-Paste in water had reached:

0.0497 ± 0.0022 mg/L at 20 ± 0.5 °C
= 0.0497 * 10-6 kg/L (SI units)
(mean value of all ten fractions ± standard deviation)

Quartz sand was filled into a glass column and coated with test item.

A flow rate of 24.76 mL/h was set. After discarding the first five column volumes, fractions were collected and measured.

On the first day, no plateau was reached (downward tendency). After five consecutive fractions on the second day, the plateau was considered as reached, because variation was less than 30% and no tendency was observed.
A second experiment with a flow rate of 12.4 mL/h was performed likewise. In this experiment, the first five fractions showed no variations greater than 30 % and no tendency.

No differences greater than 30 % in the concentrations of the solutions could be determined between the sample dates of the different flow rates, supporting the independency of solubility and flow rate.

                                       

At the plateau, the concentration of [14C] HAT-Paste in water had reached:


0.0497 ± 0.0022 mg/L at 20 ± 0.5 °C
= 0.0497 * 10-6 kg/L (SI units)

(mean value of all ten fractions ± standard deviation)


Values at Plateau

Flow rate [mL/h]

Sample No.

Concentration[µg/L]

Mean[µg/L]

Standard Deviation[µg/L]

Relative Standard Deviation[%]

24.76

6

51.1

49.0

2.3

4.7

7

49.0

8

51.0

9

45.4

10

48.8

12.4

1

45.3

49.0

2.3

4.7

2

50.9

3

48.8

4

50.8

5

48.9

 

Conclusions:
The water solubility of [14-C]HAT Paste was determined by measuring the plateau concentration of the test article.
At the plateau, the concentration of [14C] HAT-Paste in water had reached:
0.0497 ± 0.0022 mg/L at 20 ± 0.5 °C
= 0.0497 * 10-6 kg/L (SI units)
(mean value of all ten fractions ± standard deviation)
Executive summary:

Findings:                        

Quartz sand was filled into a glass column and coated with test item.

A flow rate of 24.76 mL/h was set. After discarding the first five column volumes, fractions were collected and measured.

On the first day, no plateau was reached (downward tendency). After five consecutive fractions on the second day, the plateau was considered as reached, because variation was less than 30 % and no tendency was observed.
A second experiment with a flow rate of 12.4 mL/h was performed likewise. In this experiment, the first five fractions showed no variations greater than 30 % and no tendency.

No differences greater than 30 % in the concentrations of the solutions could be determined between the sample dates of the different flow rates, supporting the independency of solubility and flow rate.

                                       

At the plateau, the concentration of [14C] HAT-Paste in water had reached:


0.0497 ± 0.0022 mg/L at 20 ± 0.5 °C
= 0.0497 * 10-6 kg/L (SI units)

(mean value of all ten fractions ± standard deviation)

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
1993-07-09 to 1994-10-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
EEC 92/69
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1981
Deviations:
no
GLP compliance:
yes
Type of method:
column elution method
Specific details on test material used for the study:
Analytical purity: >= 99.65 %
Lot/batch No.: 93.166
Key result
Water solubility:
< 0.24 mg/L
Temp.:
20 °C
pH:
6
Details on results:
The water solubility of the test article was determined to be less than the detection limit of the analytical method, i.e. < 0.24 mg/L.

No test article was detected in the eluted samples and therefore an estimate of the detection limit of the analytical method was made by comparing the analytical signal of the lowest calibration standard with the instrument noise.

The detection limit was set at twice the noise level and was determined to be less than 0.24 mg/L.

Conclusions:
The water solubility of the test article was determined to be less than the detection limit of the analytical method, i.e. 0.24 mg/L.
Executive summary:

The solubility in water of a substance is the saturation mass concentration of the test article in water at a given temperature.

Preliminary tests showed that the test article was insoluble in water. The water solubility could not be measured by the shake flask method, and for the column elution method, no volatile solvent was found for the test article. Therefore, this method was adapted and the test article eluted from a preparation using dimethyl formamide. The samples were analysed by HPLC. No test article was detected in the eluted samples and therefore an estimate of the detection limit of the analytical method was made by comparing the analytical signal of the lowest calibration standard with the instrument noise. The detection limit was set at twice the noise level and was determined to be less than 0.24 mg/L.

Description of key information

The water solubility of [14-C] HAT Paste was determined according to EU Method A 6, Water solubility, using the column elution method by measuring the plateau concentration of the test article. At the plateau, the concentration of [14C] HAT-Paste in water had reached:

0.0497 ± 0.0022 mg/L at 20 ± 0.5 °C = 0.0497 * 10E-06 kg/L (SI units) (mean value of all ten fractions ± standard deviation)

According to this result, HAT Paste can be regarded as insoluble in water (< 0.1 mg/L).

A supporting study evaluated the water solubility of HAT ISO by HPLC according to EU Guideline A.6, Water solubility and OECD guideline no. 105.  The water solubility of HAT ISO was determined to be below the analytical detection limit, i.e. < 0.24 mg/L.

Key value for chemical safety assessment

Water solubility:
0.05 mg/L
at the temperature of:
20 °C

Additional information