Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 700-064-6 | CAS number: 2105830-60-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2017-08-22 - 2018-06-27
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2018
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- other: The Guidelines for the Testing of Chemicals- Physical-Chemical Properties and Physical Hazards, 2013, 121 Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC).
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- other: HPLC column X SELECT HSS Cyano
Test material
- Reference substance name:
- Esterification product of castor oil and tetrahydromethyl-1,3-isobenzofuranedione
- EC Number:
- 700-064-6
- Cas Number:
- 2105830-60-0
- Molecular formula:
- Not applicable as this is a UVCB substance
- IUPAC Name:
- Esterification product of castor oil and tetrahydromethyl-1,3-isobenzofuranedione
- Test material form:
- liquid
- Details on test material:
- - Molecular weight: 2800-3000
- CAS Name: Castor oil, polymer with tetrahydromethyl-1,3-isobenzofurandione
- Description: Very viscous amber liquid
- Test substance storage: At room temperature in the dark under nitrogen
- Stebility under storage conditions: Stable
- Expiry date: 01 January 2009
Constituent 1
- Specific details on test material used for the study:
- Test substance code: BLKN20170414-1787
- Radiolabelling:
- no
Study design
- Test temperature:
- Column temprature 40°C
HPLC method
- Details on study design: HPLC method:
- HPLC is performed on analytical columns packed with a commercially available cyanopropyl solid phase containing non-polar and polar moieties.
While passing through the column along with the mobile phase the test substance interacts with the stationary phase. As a result of partitioning between mobile and stationary phases the test substance is retained. The dual composition of the stationary phase having polar and non-polar sites allows for interaction of polar and non-polar groups of a molecule in a similar way as is the case for organic matter in soil or sewage sludge matrices. This enables the relationship between the retention time on the column and the adsorption coefficient on organic matter to be established. According lgKoc and lgk of reference sample and to establish the calibration curve. By this calibration curve, the lgk and lgK0c of test substance were calculated.
Reference substances
Chemicals CAS Manufacturer lgKoc
Thiourea 62-56-6 Sigma -
Acetanilide 103-84-4 Sigma 1.25
Carbendazim 10605-21-7 Sigma 2.35
Linuron 330-55-2 Sigma 2.59
Methiocarb 2032-65-7 Sigma 3.10
1,2,3-Trichlorobenzene 87-61 -6 Sigma 3.16
Phenanthrene 85-01-8 Sigma 4.09
Diclofop-methyl 51338-27-3 Sigma 4.20
4,4'-DDT 50-29-3 Macklin 5.63
HPLC conditions
Instrument HPLC (Waters2695/ 2998,INS-031-03)
Column X SELECT HSS Cyano C4.6x150mm, 5μm)
Column temperature 40°c
Flow rate 1.0ml/min
Detective wave 30 scanning,210-400nm scan
lnjection volume 10μL
mobile phase Methanol
Results and discussion
Adsorption coefficient
- Key result
- Sample No.:
- #1
- Type:
- log Koc
- Value:
- > 5.63 dimensionless
Results: HPLC method
- Details on results (HPLC method):
- Thiourea was used to measure t0. Different concentrations of the reference substances were injected their retention time were recorded. The test solution with a concentration of 1207mg/L was injected and the retention time was determined and recorded. All reference- and test substances were injected and determined two times. Using methanol as the mobile phase, the retention times of the reference samples cannot be linear fit due to the strong eluent strength. According to the sample information, it belongs to no unique and identified molecular structure substance. lt shows two series peaks with the retention times of the peak1 were 2.86minute and 2.86minute respectively and the retention times of the peak2 were 3.69minute and 3.69minute respectively. According to the method, at least one reference substance with a lgKoc value above the expected lgKoc value of test substance should be used.
However, the test substance was very strong retained on the column and its lgKoc was even higher than the reference substance 4,4'-DDT with the highest lgKoc of 5.63 listed in the guideline. The adsorption coefficient (Koc) of the test substance was shown to be very high. Therefore, the lgKoc of the test substance was considered to be greater than 5.63.
The results of the reference substances
Reference substance tR1 (min) tR2 (min) ØtR (min) lg Koc
Thiourea 1.84* 1.84* 1.84* -
Acetanilide 1.90 1.90 1.90 1.25
Carbendazim 1.93 1.93 1.93 2.35
Linuron 1.95 1.95 1.95 2.59
Methiocarb 1.91 1.91 1.91 3.10
1,2,3-Trichlorobenzene 1.97 1.97 1.97 3.16
Phenanthrene 2.05 2.05 2.05 4.09
Diclofop-methyl 1.95 1.95 1.95 4.20
4,4'-DDT 1.99 1.99 1.99 5.63
-: not applied; *:t0
The results of the test substance
Sample Replicate tR (min) Area%
1 2.86 28.7
CAS 3.69 71 .3
2105830-60-0 2 2.86 35.2
3.69 64.8
Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Conclusions:
- The adsorption Coefficient (Koc) of the test substance was determined by the HPLC method. However, the test substance was very strong retained on the column and its retention time was higher than even that of the reference substance 4,4'-DDT with the highest lgKoc of 5.63. Therefore, the lgKoc of the test substance was considered to be greater than 5.63.
- Executive summary:
In the test, thiourea, acetanilide, carbendazim, linuron, methiocarb, 1,2,3 - trichlorobenzene, phenanthrene, diclofop-methyl and 4,4'-DDT were selected as reference substances. Using methanol as the mobile phase, the rentention times of the reference samples cannot be linear fit due to the strong eluent strength. According to the sample information, it belongs to no unique and identified molecular structure substance. lt shows two series peaks with the retention time of the peak1 were 2.86minute and 2.86minute respectively and the retention time of the peak2 were 3.69minute and 3.69minute respectively. According to the method, at least one reference substance
with a lgKoc value above the expected lgKoc value of test substance should be used. However, the test substance was very strong retained on the column and its retention time was even higher than the reference substance 4,4'-DDT with the highest lgKoc of 5.63 listed in the guideline. The adsorption coefficient (Koc) of the test substance was shown to be very high. Considering the uncertainty of extrapolation, the lgKoc of the test
substance was considered tobe greater than 5.63.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.