Administrative data

First-aid measures

General advice

No hazards which require special first aid measures.

If inhaled

Remove from exposure, lie down. If breathing is irregular or stopped, administer artificial respiration. Monitor breathing, give oxygen if necessary. Consult a physician.

In case of skin contact

Wash off with soap and water.

In case of eye contact

Rinse with plenty of water.

If swallowed

Consult a physician if necessary. Rinse mouth.

Most important symptoms and effects, both acute and delayed

Symptoms: No information available.

Risks: No information available.

Indication of any immediate medical attention and special treatment needed

Treatment: No information available.

Fire-fighting measures

Suitable extinguishing media

Water, Foam, Dry powder, Carbon dioxide (CO2)

Specific hazards during firefighting

Dangerous gases or fumes may occur in case of fire.

Special protective equipment for firefighters

Wear self contained breathing apparatus for fire fighting if necessary.

Further information

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Accidental release measures

Personal precautions

Handle in accordance with good industrial hygiene and safety practice.

Special precautions

Forms slippery/greasy layers with water.

Environmental precautions

Avoid subsoil penetration.

Do not flush into surface water or sanitary sewer system.

Methods for cleaning up

Use mechanical handling equipment. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Handling and storage

Precautions for safe handling

Advice on safe handling

No special technical protective measures required.

Advice on protection against fire and explosion

Normal measures for preventive fire protection.

7.2 Conditions for safe storage, including any incompatibilities

Requirements for storage areas and containers       No special storage conditions required.

Storage class (TRGS 510)       10: Combustible liquids not in Storage Class 3

Other data       Protect from frost, heat and sunlight.

7.3 Specific end use(s)

Specific use(s)

This information is not available.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
not dangereous goods

Exposure controls / personal protection

PERSONAL PROTECTIVE EQUIPMENT

Respiratory protection       No personal respiratory protective equipment normally required. In inadequately ventilated areas, where workplace limits are exceeded, where unpleasant odours exist or where aerosols are in use, or smoke and mist occur, use self-contained breathing apparatus or breathing apparatus with a type A filter or appropriate combined filter (e.g. where aerosols are in use, or smoke and mist occur, A-P2 or ABEK-P2), in compliance with EN 141.

Hand protection       The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other., Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time., Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside influences (e.g. temperature).

gloves suitable for permanent contact:

Material: butyl-rubber

Break through time: >= 480 min

Material thickness: >= 0.7 mm

gloves suitable for splash protection:

Material: Nitrile rubber/nitrile latex

Break through time: >= 30 min

Material thickness: >= 0.4 mm

Eye protection       Safety glasses

Skin and body protection       Protective suit

Hygiene measures       General industrial hygiene practice.

Protective measures       No special protective equipment required.

ENVIRONMENTAL EXPOSURE CONTROLS

General advice

Avoid subsoil penetration.

Do not flush into surface water or sanitary sewer system.

Stability and reactivity

Stable at normal ambient temperature and pressure.

No decomposition if stored and applied as directed.

Hazardous reactions

None known.

Conditions to avoid

Direct heating, dirt, chemical contamination, sunlight, UV or ionising radiation.

Materials to avoid

None known.;

Hazardous decomposition products

No decomposition if stored normally.

Thermal decomposition

No decomposition if used as directed.

Disposal considerations

Waste treatment methods

Product

Can be incinerated, when in compliance with local regulations.

Contaminated packaging

Empty remaining contents.

waste code of the European Union: EWC

A waste code in accordance with the European Waste Catalogue (EWC) may not be assigned to this product since it admits of a classification only when the consumer uses it for some purpose. The waste code must be determined in agreement with the regional waste disposal authority or company.