Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
toxicity to microorganisms
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Experimental data from peer reviewed journal
Qualifier:
according to guideline
Guideline:
other: Refer below principle
Principles of method if other than guideline:
Microtox test: The test exposes luminescent organisms in Microtox Acute Reagent to aqueous samples, and measures the increase or decrease in light output by the test organisms.Reagent contains living luminescent bacteria that have been grown under optimal conditions, harvested,and then lyophilized (freeze-dried). The lyophilized bacteria are rehydrated with Reconstitution Solution to provide a ready-to-use suspension of organisms. The test system measures the light output of the luminescent bacteria after they have been challenged by a sample and compares it to the light output of a control (reagent blank) that contains no sample. A difference in light output (between the sample and the control) is attributed to the effect of the sample on the organisms.
GLP compliance:
not specified
Analytical monitoring:
not specified
Vehicle:
not specified
Test organisms (species):
Photobacterium phosphoreum
Test type:
static
Water media type:
freshwater
Total exposure duration:
30 min
Remarks on exposure duration:
5-30 min. exposure period
Hardness:
No data
Test temperature:
15 degC
pH:
range of 5< pH <9
Dissolved oxygen:
No data
Salinity:
No data
Conductivity:
No data
Nominal and measured concentrations:
No data
Details on test conditions:
No data
Reference substance (positive control):
yes
Key result
Duration:
30 min
Dose descriptor:
EC50
Effect conc.:
86.4 mg/L
Nominal / measured:
meas. (not specified)
Conc. based on:
test mat.
Basis for effect:
other: viability and sensitivity
Validity criteria fulfilled:
not specified
Conclusions:
The median effective concentration (EC50) for the test substance, in microorganism (Photobacterium phosphoreum) in a 5-30 minute study on the basis of viability and sensitivity effect was observed to be 86.4 mg/L.
Executive summary:

The test exposes luminescent organisms in Microtox Acute Reagent to aqueous samples, and measures the increase or decrease in light output by the test organisms.Reagent contains living luminescent bacteria that have been grown under optimal conditions, harvested,and then lyophilized (freeze-dried). The lyophilized bacteria are rehydrated with Reconstitution Solution to provide a ready-to-use suspension of organisms. The test system measures the light output of the luminescent bacteria after they have been challenged by a sample and compares it to the light output of a control (reagent blank) that contains no sample. A difference in light output (between the sample and the control) is attributed to the effect of the sample on the organisms.The median effective concentration (EC50) for the test substance, in microorganism (Photobacterium phosphoreum) in a 5-30 minute study on the basis of viability and sensitivity effect was observed to be 86.4 mg/L.

Description of key information

Toxicity to microorganisms:

The test exposes luminescent organisms in Microtox Acute Reagent to aqueous samples, and measures the increase or decrease in light output by the test organisms.Reagent contains living luminescent bacteria that have been grown under optimal conditions, harvested,and then lyophilized (freeze-dried). The lyophilized bacteria are rehydrated with Reconstitution Solution to provide a ready-to-use suspension of organisms. The test system measures the light output of the luminescent bacteria after they have been challenged by a sample and compares it to the light output of a control (reagent blank) that contains no sample. A difference in light output (between the sample and the control) is attributed to the effect of the sample on the organisms.The median effective concentration (EC50) for the test substance, in microorganism (Photobacterium phosphoreum) in a 5-30 minute study on the basis of viability and sensitivity effect was observed to be 86.4 mg/L.

Key value for chemical safety assessment

EC50 for microorganisms:
86.4 mg/L

Additional information

Toxicity to microorganisms:

The test exposes luminescent organisms in Microtox Acute Reagent to aqueous samples, and measures the increase or decrease in light output by the test organisms.Reagent contains living luminescent bacteria that have been grown under optimal conditions, harvested,and then lyophilized (freeze-dried). The lyophilized bacteria are rehydrated with Reconstitution Solution to provide a ready-to-use suspension of organisms. The test system measures the light output of the luminescent bacteria after they have been challenged by a sample and compares it to the light output of a control (reagent blank) that contains no sample. A difference in light output (between the sample and the control) is attributed to the effect of the sample on the organisms.The median effective concentration (EC50) for the test substance, in microorganism (Photobacterium phosphoreum) in a 5-30 minute study on the basis of viability and sensitivity effect was observed to be 86.4 mg/L.