Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study according to OECD Guideline 209

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994
Report date:
1995

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Sodium N-(2,3-dihydro-2-oxo-1H-benzimidazol-5-yl)-3-hydroxynaphthalene-2-carboxamidate
EC Number:
278-575-4
EC Name:
Sodium N-(2,3-dihydro-2-oxo-1H-benzimidazol-5-yl)-3-hydroxynaphthalene-2-carboxamidate
Cas Number:
76918-62-2
Molecular formula:
C18H13N3O3.Na

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
no
Details on test solutions:
PREPARATION OF TEST SOLUTION

Preparation of the saturated solution: The test item was weighed out (500 and 1000 mg/L ) directly into the test vessels.

Test organisms

Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Origin: Municipal sewage treatment plant of Sindlingen (Frankfurt)
- non-adapted activated sludge, receives predominantly municipal sewage and hardly industrial chemical waste

Study design

Test type:
static
Limit test:
yes
Total exposure duration:
3 h

Test conditions

Test temperature:
19,2 - 20,6°C
pH:
7,0 - 7,1
Nominal and measured concentrations:
Nominal concentration: 500 mg/L , 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel:
- glass flasks, diameter 60 mm, height 170 mm
- fill volume: appr. 480 mL
- Aeration: permanent
- No. of vessels per concentration (replicates): 2
- No. of vessels per control (replicates): 3

TEST MEDIUM
- according to Directive 88/302/EEC, Part C and OECD guideline 209

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
- the pH-value of the activated sludge was measured prior to testing
- the temperature in the measuring cell was determined once durcing the measurement

TEST CONCENTRATIONS
- Test concentrations: 500 mg/L, 1000 mg/L
- 3 control replicates without test item were included.
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol

Results and discussion

Effect concentrationsopen allclose all
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 h
Dose descriptor:
other: EC20
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 h
Dose descriptor:
other: EC80
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate

Any other information on results incl. tables

Table 1: Respiration rates and inhibition of respiration of test and reference item concentrations

 

Respiration Rate

[mg O2/L x h]

Inhibition [%]

Mean

Control 1

52.8

-

54.4 mg O2/L x h

Control 2

55.2

-

Control 3

55.2

-

DCP* 5 mg/L

42.0

22.8

-

DCP 20 mg/L

18.0

66.9

-

DCP 30 mg/L

15.6

71.3

-

Test item 500 mg/L

50.4

7.4

6.2 %

Test item 500 mg/L

51.6

5.1

Test item 1000 mg/L

55.2

-1.5

-1.5 %

Test item 1000 mg/L

55.2

-1.5

DCP = 3,5 -dichlorophenol

Applicant's summary and conclusion

Conclusions:
The test item is not toxic at concentration