EC number: 405-430-6 | CAS number: 65143-89-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Emergency measure - Inhalation: Not considered to be inhalable although the substance has a
faint odour. If any person feels uncomfortable or unwell in
the presence of the substance, move to area of fresh
air.Seek medical advice if signs of discomfort persist.
Emergency measure - Eyes: Wash thoroughly with water. If signs of discomfort, seek
medical advice.
Emergency measure - Skin: Wash area with water. If signs of discomfort, seek medical
advice
Emergency measure - Ingestion: Drink plenty of water. If signs of discomfort, seek medical
advice.
Fire-fighting measures
Recommended extinguishing agent: Carbon dioxide, powder, foam and water spray considered
suitable.
Product arising from burning: Oxides of sulphur and carbon will be formed during
combustion. Incomplete combustion may lead to partially
oxidised organic derivatives and acidic gases.
Product determined by test: N
Protective equipment: Gloves, goggles and breathing apparatus recommended.
Equipment and protective clothing should be washed with
water after contamination.
Accidental release measures
Emergency measures in case of spillage: Absorb onto sand, sawdust or other suitable material and
dispose as hazardous waste. Wash contaminated areas with
water, avoiding contamination of water courses.
Handling and storage
Handling: Avoid eye contact. Avoid breathing mist. Avoid trapping
material under clothing.
Storage: Storage area to be equipped with spill collection systems.
Packaging of the substance and or preparation: Lacquered steel drums
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: Class 9-11C UN no.:3082 Kemler: 90
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: No other known dangers arising from the normal use, storage,
transport or disposal of the substance or preparation.
Chemical reaction with water: Significantly soluble with water and no known reaction.
Dust explosion: Material does not exist in the form of a powder or dust.
Dust explosion determined by test: N
Disposal considerations
Industry - Possibility of recovery/recycling: Not possible
Industry - Possibility of neutralisation: Not applicable
Industry - Possibility of destruction: controlled discharge: Not possible
Industry - Possibility of destruction - incineration: Not possible
Industry - Possibility of destruction - water purification: Not applicable.
Industry - Possibility of destruction - other: Not applicable
Public at large - Possibility of recovery/recycling: Not applicable
Public at large - Possibility of neutralisation: Not applicable
Public at large - Possibility of destruction: controlled discharge: Not applicable
Public at large - Possibility of destruction - incineration: Not applicable
Public at large - Possibility of destruction - water purification: Not applicable
Public at large - Possibility of destruction - others: Not applicable
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.