Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 Feb 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2022
Report date:
2022

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: isothermal thermogravimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
4-Amino-2-fluoro-benzamide
EC Number:
809-434-2
Cas Number:
609783-45-1
Molecular formula:
C7H7FN2O
IUPAC Name:
4-Amino-2-fluoro-benzamide

Results and discussion

Vapour pressure
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 Pa
Remarks on result:
other: mean of three measurements

Any other information on results incl. tables

The measurement of the vapour pressure was performed in the temperature range between 100 °C and 140 °C. For the evaluation, the reproducible weight loss values above 1 µg/min of the temperature steps between 110 °C and 130 °C have been considered.


The plot of log VT of the test item as function of the reciprocal temperatures. The coefficient of correlation (R2) was 0.9863.


Inserting the equation for log VT above, the following equation for the temperature dependence of the vapour pressure of the test item is obtained:


logPT = 5.1909 + 1.1972 * (-5216.2 * 1/T + 9.7485)


With this equation, the following vapour pressure results were obtained:


3.53 ∙ 10-5 Pa at 20 °C resp. 8.05 ∙ 10-5 Pa at 25 °C.


 


 


 

Applicant's summary and conclusion

Conclusions:
The isothermal thermogravimetrical effusion method was applied for the deter-mination of the vapour pressure of the test item.
A value of the vapour pressure of the test item was assessed using the data ob-tained between 110 °C and 130 °C. The vapour pressure of the test item was estimated to be
3.53 x 10-5 Pa at 20 °C resp. 8.05 x 10-5 Pa at 25 °C.


Executive summary:

Test Design: The vapour pressure of the test item at 20 °C und 25 °C (PT, 20 resp. PT, 25) was determined using the isothermal thermogravimetrical effusion method. According to the guideline, this method was validated in the range 10-10 to > 1 Pa using a set of reference substances with known vapour pressures. 


Results/Conclusion: The isothermal thermogravimetrical effusion method was applied for the determination of the vapour pressure of the test item. A value of the vapour pressure of the test item was assessed using the data obtained between 110 °C and 130 °C. The vapour pressure of the test item was estimated to be 3.53 x 10-5 Pa at 20 °C resp. 8.05 x 10-5 Pa at 25 °C.