Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Auto flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- auto-ignition temperature (liquids)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1999-09-27 to 1999-10-01
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
- Deviations:
- not specified
- GLP compliance:
- yes
- Key result
- Auto-ignition temperature:
- 255 °C
- Atm. press.:
- >= 1 001 - <= 1 004.8 hPa
- Conclusions:
- SANTICIZER 2148 PLASTICIZER is auto-ignitable, with an auto-ignition temperature of 225°C.
- Executive summary:
Samples were injected by means of a variable volumetric pipette to assure a rapid injection. The time lag between injection and ignition was measured for all tests. Approx. 5 mins after each test substances injection, the test vessel was flushed completely with clean air. After flushing, a sufficient time interval was allowed to ensure that the flask temperature was stabilised at the desired test temperature before the next sample was injected.
A preliminary test was carried out, starting at 200°C and testing every 20°C, a flame was observed at 380°C. Going down from 387°C and testing every 5°C, an auto-ignition temperature of 322°C was determined. Main study was carried out, determining the lowest auto-ignition temperature as 258°C, with an injection volume of 150μl and a time lag of 36 s, as the atmospheric pressure varied between 1001.0 and 1004.8 hPa.
SANTICIZER 2148 PLASTICIZER is auto-ignitable, with an auto-ignition temperature of 225°C.
The auto-ignition temperature is the lowest temperature at which the test substance will ignite with mixed with air under the conditions defined in the test method.
Deviations meet the criteria as outlined in the protocol (repeatability<10°C when an auto-ignition temperature <300°C is determined)
Reference
See table for the summary of the results of the main study
Test number |
Auto-ignition temperature (°C) |
Injected volume (μl) |
Time lag (s) |
Test 1 |
300 |
70 |
9 |
262 |
150 |
33 |
|
262 |
175 |
30 |
|
300 |
250 |
12 |
|
Test 2 |
266 |
100 |
21 |
260 |
150 |
33 |
|
268 |
200 |
23 |
|
Test 3 |
308 |
100 |
08 |
258 |
150 |
36 |
|
294 |
250 |
11 |
Description of key information
Santicizer 2148 is auto-ignitable, with an auto-ignition temperature of 225°C.
Key value for chemical safety assessment
Additional information
A key EU Method A.15 study was conducted to determine the auto-ignition temperature of Santicizer 2148 Plasticizer (NOTOX B.V., 1999g).
The auto-ignition temperature of Santicizer 2148 was determined to be 225°C.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.