Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 May to 20 May 2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: Commission Directive 88/302/EEC; Official Journal of the EG L133 Part C (1988)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: Direct weighing into test flasks
- Controls: Yes, blank control
- Test concentration separation factor: 1.8
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Laboratory culture: mixed population of aquatic microorganisms(activated sludge)
- Name and location of sewage treatment plant where inoculum was collected: aeration tank of a domestic sewage treatment plant(Wupper area water authority)
- Method of cultivation: Stirring period of test item before start of incubation time: 16 h.
- Initial biomass concentration: 480 mg/L
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Test temperature:
20 +/- 2 °C
Nominal and measured concentrations:
10, 18, 32, 56, 100 mg/L as nominal concentrations of the test item.
Details on test conditions:
TEST SYSTEM
- Test vessel: Flask
- Aeration: Permanent aeration
- No. of vessels per concentration (replicates): 1
- No. of vessels per control (replicates): 2 controls
- Sludge concentration (weight of dry solids per volume): 480 mg/L suspended solids
- Nutrients provided for bacteria: Daily feed with synthetic medium

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : respiration inhibition at 3 h.
TEST CONCENTRATIONS
- Spacing factor for test concentrations: 1.8
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
44 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
- Effect concentrations exceeding solubility of substance in test medium: The solubility was not exceeded.
- Blank controls oxygen uptake rate: 34 mg/L
Results with reference substance (positive control):
- Results with reference substance valid? Yes, all validity criteria are fulfilled.
- Relevant effect levels: 0 % inhibition at 2.5 mg/L, 82.4 % inhibition at 40 mg/L.

Validity criteria for the measurement of the toxicity to microorganisms:

























Target condition according to guideline:Actual condition according to the study:Validity criteria met:

In a 2004 international ring test organized by ISO using activated sludge derived from domestic sewage, the EC50 of 3,5-dichlorphenol was found to lie in the range 2 mg/L to 25 mg/L for total respiration, 5 mg/L to 40 mg/L for heterotrophic respiration and 0.1 mg/L to 10 mg/L for nitrification respiration. If the EC50 of 3,5-DCP does not lie in the expected range, the test should be repeated with activated sludge from another source.


The EC 50 of the reference substance 3.5-dichlorophenol is in the range 5 - 30 mg/L, which is 5 mg/L above the range specified in the guideline. Considering the small deviation, this criterion is considered to be met.Yes
The test should be performed at a temperature within the range 20 ± 2°C.The test temperature was 20 ± 2°C.Yes
The EC50 and, if possible, 95 % confidence limits, possibly EC20, EC80; possibly NOEC and the used statistical methods, if the EC50 cannot be determined shall be reported.The EC50 including the 95% confidence limits are stated. The EC values were determined by probit analysis.Yes

 

Validity criteria fulfilled:
yes
Remarks:
See 'Any other information on results incl. tables'.
Conclusions:
EC50 (3 h): 44 mg/L
Executive summary:

The test item showed 100 % respiration inhibition of activated sludge at a test item concentration of 10000 mg/L. The EC50 was determined to be 44 mg/L.

Description of key information

The test item showed 100 % respiration inhibition of activated sludge at a test item concentration of 10000 mg/L. The EC50 was determined to be 44 mg/L.

Key value for chemical safety assessment

EC50 for microorganisms:
44 mg/L

Additional information