Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2021
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 021
- Report date:
- 2021
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- July 1995
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Version / remarks:
- January 2014
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- flask method
Test material
- Reference substance name:
- Low molecular weight organic substances from fast pyrolysis bio-oil
- IUPAC Name:
- Low molecular weight organic substances from fast pyrolysis bio-oil
- Reference substance name:
- Monomers from fast pyrolysis bio-oil
- IUPAC Name:
- Monomers from fast pyrolysis bio-oil
- Reference substance name:
- Dimers from fast pyrolysis bio-oil
- IUPAC Name:
- Dimers from fast pyrolysis bio-oil
- Reference substance name:
- Trimers from fast pyrolysis bio-oil
- IUPAC Name:
- Trimers from fast pyrolysis bio-oil
- Reference substance name:
- Higher oligomers from fast pyrolysis bio-oil
- IUPAC Name:
- Higher oligomers from fast pyrolysis bio-oil
- Reference substance name:
- Water
- EC Number:
- 231-791-2
- EC Name:
- Water
- Cas Number:
- 7732-18-5
- Molecular formula:
- H2O
- IUPAC Name:
- water
- Test material form:
- liquid: viscous
- Remarks:
- Brown /black highly vicous liquid
Constituent 1
Constituent 2
Constituent 3
Constituent 4
Constituent 5
Constituent 6
Results and discussion
Water solubilityopen allclose all
- Key result
- Water solubility:
- 8.89 mg/L
- Conc. based on:
- test mat.
- Loading of aqueous phase:
- 51 mg/L
- Incubation duration:
- 20 d
- Temp.:
- 20 °C
- pH:
- >= 4 - <= 6
- Key result
- Water solubility:
- 225 mg/L
- Conc. based on:
- test mat.
- Loading of aqueous phase:
- 1 003 mg/L
- Incubation duration:
- 20 d
- Temp.:
- 20 °C
- pH:
- >= 4 - <= 6
- Details on results:
- A strong dependency of the solubility on the amount of the test item (nominal load) was perceived in the flasks 1 – 6.
As the solubility was dependent on the nominal concentration, no exact value for the solubility of the test item in water can be stated. Dependency of the pH value on the amount of the test item (nominal load) was also perceived in the main test. Therefore, the concentration of the test item in water was stated as 0.85 – 225 mg/L at 20.0 °C
Any other information on results incl. tables
Measurements during Equilibration
Day |
Flask |
Conc. DOC Mean |
Conc. DOC – blank |
Conc. test item |
1 |
1A |
29.4 |
28.9 |
47.5 |
2 |
1B |
34.9 |
34.3 |
56.4 |
3 |
1C |
38.4 |
37.8 |
62.1 |
3 |
blank |
0.58 |
- |
- |
4 |
1A |
42.7 |
42.1 |
69.2 |
5 |
1B |
42.4 |
41.9 |
68.8 |
6 |
1C |
51.8 |
51.2 |
84.2 |
7 |
1B |
47.4 |
46.8 |
76.9 |
8 |
1C |
60.8 |
60.2 |
99.0 |
1A |
50.1 |
49.5 |
81.4 |
|
9 |
1B |
50.1 |
49.5 |
81.4 |
10 |
1C |
65.2 |
64.7 |
106 |
11 |
1A |
56.7 |
56.1 |
92.2 |
12 |
1B |
56.3 |
55.7 |
91.5 |
13 |
1C |
75.0 |
74.4 |
122 |
1A |
61.8 |
61.2 |
101 |
|
14 |
1B |
60.6 |
60.0 |
98.7 |
15 |
1C |
81.0 |
80.4 |
132 |
1A |
65.8 |
65.2 |
107 |
|
16 |
1B |
61.3 |
60.7 |
99.8 |
17 |
1C |
84.9 |
84.4 |
139 |
18 |
1A |
66.8 |
66.2 |
109 |
19 |
1B |
61.5 |
60.9 |
100 |
20 |
1C |
85.9 |
85.3 |
140 |
pH was 5 – 6 (determined with indicator paper) and temperature was 20 °C at all sampling times
A minimal amount of DOC was measured in the blank solution after filtration, therefore the measured value of the blank flask was subtracted from the measured values in the flasks 1A – 1C.
Flask 1C showed a darker colour and significantly higher test item concentrations than flasks 1A and 1B, therefore the evaluation of the equilibration phase was based on each flask individually.
No more significant rising tendency was observed in flasks 1A and 1B between days 15 and 19, and as also Flask 1C showed no more significant increase in test item concentration between day 17 and day 20. The small increase was caused by change of the nominal load in the bottle due to repeated samplings. Therefore, the plateau was considered as reached and the final sampling was performed on day 20.
Measurements at Plateau
Flask |
Temperature [°C] |
pH* |
Concentration DOC Mean [mg/L] |
Conc. DOC – blank [mg/L] |
Conc. test item [mg/L] |
2 |
20.0 |
6.03 |
1.09 |
0.51 |
0.85 |
3 |
20.0 |
5.24 |
5.98 |
5.40 |
8.89 |
4 |
20.0 |
5.07 |
9.19 |
8.61 |
142 |
5 |
20.0 |
4.30 |
88.22 |
87.6 |
144 |
6 |
20.0 |
4.09 |
137.21 |
137 |
225 |
The measured value in the blank flask 0.58 mg/L was subtracted from the measured value in the flasks 2 – 6.
Results
The measurements on day 20 (flasks 1A, 1B and 3 – 6) were included in the calculation of the solubility of the test item in water. Flask 1C was excluded from calculations because the test item concentration was significantly higher in Flask C throughout the equilibration phase.
Flask # |
Conc. test item [mg/L] |
Nominal Conc. Test Item [mg/L] |
Dissolved Part [%] |
2 |
0.85 |
11 |
8.0 |
3 |
8.89 |
51 |
17.3 |
4 |
142 |
103 |
13.8 |
1* |
144 |
502 |
20.8 |
5 |
225 |
750 |
19.2 |
6 |
0.85 |
1003 |
22.4 |
*mean value of flasks 1Aand 1B
Conclusion
As solubility was dependent on nominal concentration, no exact value for the solubility of the test item in water can be stated. The solubility range for the tested nominal concentration 11–1003g/L is 8.89–225 mg/L at 20.0 ± 0.5 °C (8.89–225 * 10-3kg/m3in SI units), corresponding to 8.0–22.4 % of the test item relating to the nominal concentration of the test item (Mean value 16.9 % with standard deviation 5.3 %).
Applicant's summary and conclusion
- Conclusions:
- The water solubility was found to be dependent on the nominal concentration. Therefore, the solubility range for the tested nominal concentration 11 – 1003 mg/L is 0.85 – 225 mg/L at 20.0 ± 0.5 °C, corresponding to 8.0 – 22.4 % of the test item relating to the nominal concentration of the test item (Mean value 16.9 % with standard deviation 5.3 %).
- Executive summary:
The solubility of the test item in water was determined, according to OECD 105, by
measurement of DOC concentration in the filtrated test solutions using TOC analyser.
During pre-tests for development of a specific analytical method several marker component candidates were tested for quantification of this UVCB substance via LC/MS/MS analysis. As the water solubility of components in UVCB substances can differ substantially, it was considered inadequate to base the water solubility of the mixture on a number of specific components because no information on the solubility of the remaining components is possible.
Therefore, the determination of total organic carbon was favored, because the solubility of the sum of all components is recorded and thus more meaningful information is generated.
As the test item is a UVCB substance, six different loading rates of the test item were chosen to study the effect of the loading rate on the measured water solubility: 10, 50, 100, 500, 750 and 1000 mg/L. Three flasks (1A – 1C) with the same loading rate (500 mg/L) were used during equilibration. Seven vessels (flasks blank, 1C (for the sampling point 72 h) and 2 – 6) were set onto the shaking apparatus immediately and shaking at 150 rpm was started. After 24 ± 2 hours, flask 1B (for the sampling point 48 h) and after 48 ± 2 hours, flask 1A (for the sampling point 24 h) were set on the shaker and all flasks were shaken for further 24 ± 2 hours at room temperature. Then, flasks 1A – 1C were removed from the shaker, tempered at 20.0 ± 0.5 °C, samples were taken, membrane filtered and analysed for DOC via TOC analyser. Due to an upward tendency of the test item concentration, the test was prolonged and the flasks 1A – 1C were sampled and analysed until day 20. As flask 1C showed a much darker color throughout the test than flask 1A and 1B, 1C was not included in the evaluation of the plateau. The final measurement was performed as determination from flasks 2 – 6 on day 20.
DOC was measured via TOC analyser in the saturated aqueous solutions. The pH value in the flasks 2 – 6 lay in the range of 4.09 – 6.03.
No Tyndall effect (i.e. a laser beam was not scattered when transmitted through the liquid) could be observed indicating that no colloidal dispersed particles were present.
A strong dependency of the solubility on the amount of the test item (nominal load) was perceived in the flasks 1 – 6.
As the solubility was dependent on the nominal concentration, no exact value for the solubility of the test item in water can be stated. Dependency of the pH value on the amount of the test item (nominal load) was perceived in the main test.
Therefore, the concentration of the test item in water was stated as
0.85 – 225 mg/L at 20.0 ± 0.5 °C
0.85 – 225 * 10-3kg/m3(SI units)
for the following nominal concentration range of the test item in water: 10 – 1000 mg/L, corresponding to a dissolved part of 16.9 ± 5.3 % of the test item (mean value ± standard deviation) relating to the nominal concentration of the test item.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.