Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Auto-ignition temperature:
ca. 336 °C
Atm. press.:
> 991 - < 992 hPa
Remarks on result:
preliminary test
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
explosive properties of explosives
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Type of method:
equilibrium method closed cup
Flash point:
125 °C
Atm. press.:
1 013 hPa
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
oxidising liquids
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Type of method:
effusion method: vapour pressure balance

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0.028 Pa

Applicant's summary and conclusion