Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air, seek medical attention.

Emergency measure - Eyes: Wash with water for 15 minutes.

Emergency measure - Skin: Wash with plenty of water.

Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Water, carbon dioxide and

dry powder

Product arising from burning: Products arising from pyrolysis: Carbon and nitrogen oxides

and hydrogen chloride gas.

Protective equipment: Protective equipment: Wear protective clothing and a

self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Collect spilt material and dispose of by incineration at an

authorised facility.

Handling and storage

Handling: Avoid dust formation Avoid contact with skin and eyes. Do

not inhale dust.

Storage: No special precautions

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: None reported

Chemical reaction with water: Chemical reaction with water: None reported

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible

Industry - Possibility of neutralisation: None known

Industry - Possibility of destruction: controlled discharge: Not recommended

Industry - Possibility of destruction - incineration: Recommended method, using a suitable facility. Waste gas

treatment to remove nitrogen oxides and hydrogen chloride

should be used.

Industry - Possibility of destruction - water purification: Not recommended

Public at large - Possibility of recovery/recycling: The substance itself will not enter the public domain.

Articles containing the substance may be disposed of as

domestic waste.