Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-303-8 | CAS number: 7488-56-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 21 September 2017 to 27 September 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 438 (Isolated Chicken Eye Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Deviations:
- no
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- EU method B.48 (Isolated chicken eye test method for identifying occular corrosives and severe irritants)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Selenium disulphide
- EC Number:
- 231-303-8
- EC Name:
- Selenium disulphide
- Cas Number:
- 7488-56-4
- Molecular formula:
- S2Se
- IUPAC Name:
- selenium disulphide
- Test material form:
- solid: particulate/powder
Constituent 1
- Specific details on test material used for the study:
- Name: Selenium Disulphide
CAS Number: 7488-56-4
Batch number: PMC / 285 / 16
Appearance: Orange/yellow powder
Expiry date: 24 November 2019
Purity: 100%
Storage conditions: Room temperature (between 5oC and 30oC), protected from light
Safety precautions: Enhanced safety precautions were applied considering the supplied safety datasheet to assure personnel health and safety.
Test animals / tissue source
- Species:
- chicken
- Strain:
- other: ROSS 308
- Details on test animals or tissues and environmental conditions:
- Strain of chicken: ROSS 308
Source: TARAVIS KFT. (Address: 9600 Sárvár, Rábasömjéni út. 129., Hungary)
Chicken heads were collected after slaughter in a commercial abattoir from chickens (approximately 7 weeks old) which are used for human consumption. Heads were collected by a slaughter house technician and heads transported to CiToxLAB Hungary Ltd. at ambient temperature at the earliest convenience. After collection, the heads were inspected for appropriate quality and wrapped with tissue paper moistened with saline, then placed in a plastic box which was closed (4-5 heads per box). The heads were received at CiToxLAB Hungary Ltd. and processed within 2 hours of collection in each experiment.
The appropriate number of eyes was selected and after being placed in the superfusion apparatus. There they were examined again with the slit lamp microscope to ensure that they were in good condition. The focus was adjusted to see clearly the physiological saline which was flowing on the cornea surface. Eyes with a high baseline fluorescein staining (i.e., > 0.5) or corneal opacity score (i.e., > 0.5) were rejected. The cornea thickness was measured, any eye with cornea thickness deviating more than 10 % from the mean value for all eyes, or eyes that showed any other signs of damage, were rejected and replaced. If the selected eyes were appropriate for the test, acclimatization started and it was conducted for approximately 45 to 60 minutes. The chambers of the superfusion apparatus were at controlled temperature (32±1.5°C) during the acclimatization and treatment periods.
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- 30 mg
- Duration of treatment / exposure:
- 10 seconds
- Observation period (in vivo):
- Not applicable
- Duration of post- treatment incubation (in vitro):
- 4 hours
- Number of animals or in vitro replicates:
- 2 replicates per group (test material, positive control, negative control)
- Details on study design:
- SELECTION AND PREPARATION OF EYES FOR THE TEST
Eyes selection
After removing the head from the plastic box, it was put on soft paper. The eyelids were carefully cut away with scissors, avoiding damaging the cornea. One small drop of 2% (w/v) fluorescein solution was applied onto the cornea surface for a few seconds and subsequently rinsed off with 20 mL physiological saline. Then the fluoresceintreated cornea was examined with a hand-held slit lamp or slit lamp microscope, with the eye in the head, to ensure that the cornea was not damaged. If the cornea was in good condition, the eyeball was carefully removed from the orbit.
Preparation of eyes
The eye ball was carefully removed from the orbit by holding the nictitating membrane with a surgical forceps, while cutting the eye muscles with bent scissors. Care was taken to remove the eyeball from the orbit without cutting off the optical nerve too short. The procedure avoided pressure on the eye while removing the eyeball from the orbit, in order to prevent distortion of the cornea and subsequent corneal opacity. Once removed from the orbit, the eye was placed onto damp paper and the nictitating membrane was cut away with other connective tissue. The prepared eyes were kept on the wet papers in a closed box so that the appropriate humidity was maintained.
Eyes examination and acclimatization time
The prepared eye was placed in a steel clamp with the cornea positioned vertically with the eye in the correct relative position (same position as in the chicken head). Again avoid too much pressure on the eye by the clamp. Because of the relatively firm sclera of the chicken eyeball, only slight pressure was needed to fix the eye properly.
The clamp with the eyeball was transferred to a chamber of the superfusion apparatus. The clamp holding the eye was positioned in such a way that the entire cornea was supplied with physiological saline solution dripping from a stainless steel tube, at a rate of approximately 3-4 drops/minute or 0.1 to 0.15 mL/minutes. The door of the chamber was closed except for manipulations and examinations, to maintain temperature and humidity.
The appropriate number of eyes was selected and after being placed in the superfusion apparatus. There they were examined again with the slit lamp microscope to ensure that they were in good condition. The focus was adjusted to see clearly the physiological saline which was flowing on the cornea surface. Eyes with a high baseline fluorescein staining (i.e., > 0.5) or corneal opacity score (i.e., > 0.5) were rejected. The cornea thickness was measured, any eye with cornea thickness deviating more than 10 % from the mean value for all eyes, or eyes that showed any other signs of damage, were rejected and replaced. If the selected eyes were appropriate for the test, acclimatization started and it was conducted for approximately 45 to 60 minutes. The chambers of the superfusion apparatus were at controlled temperature (32±1.5°C) during the acclimatization and treatment periods.
Identification
The eyes were identified by chamber number, marked on the door of the chamber.
The baseline assessments
At the end of the acclimatization period, a zero reference measurement was recorded for cornea thickness and opacity to serve as a baseline (t=0) for each individual eye. The cornea thickness of the eyes should not change by more than 5% within the -45 min and the zero time. No changes in thickness (0.0%) were observed in the eyes in each experiment. Following the equilibration period, the fluorescein retention was measured. Baseline values were required to evaluate any potential test item related effect after treatment. All eyes were considered to be suitable for the assay.
Treatment
After the zero reference measurements, the eye in its retainer was taken out of the chamber and placed on a layer of tissue with the cornea facing upwards. The eye was held in horizontal position, while the test material was applied onto the centre of the cornea. In each experiment, 30 mg of the test item was applied onto the entire surface of the cornea attempting to cover the cornea surface uniformly with the test item, taking care not to damage or touch the cornea.
In each experiment negative control eye was treated with 30 μL of physiological saline; positive control eyes were treated with 30 mg powdered Imidazole.
One eye was treated with physiological saline, three eyes with the test item and another three with powdered Imidazole in each experiment.
Test item removal
The time of application was noted, then after an exposure period of 10 seconds from the end of the application the cornea surface was rinsed thoroughly with 20 mL physiological saline solution at ambient temperature, taking care not to damage the cornea but attempting to remove all residual test material if possible.
Additional gentle rinsing with 20 mL saline was performed at each time point when the test item or positive control material remaining on the cornea was observed in the experiments. The test item treated eyes were rinsed additional gentle rinsing with 20 mL saline after treatment in Experiment II.
Note: Physiological saline (Manufacturer: B. Braun Pharmaceuticals SA, Lot number: 72034Y05-1,
Expiry date: 30 April 2020) was used for rinsing.
Observation and assessment of corneal effects
The control eyes and test eyes were evaluated pre-treatment and at approximately 30, 75, 120, 180 and 240 minutes after the post-treatment rinse. Minor variations within approximately ±5 minutes were considered acceptable.
Corneal thickness and corneal opacity were measured at all time points. Fluorescein retention was measured on two occasions, at baseline (t=0) and approximately 30 minutes after the post-treatment rinse. Haag-Streit Bern 900 slit-lamp microscope was used for the measurements.
Retention of chicken’s eyes
At the end of the procedure, the corneas of the eyes were carefully removed from the eyes and placed individually into labelled containers of preservative fluid (10% neutral buffered formalin, Manufacturer: Reanal, Batch number: KTM20001, Expiry date: March 2019) was used for potential histopathology and stored at room temperature.
Classification criteria:
The following criteria is used to identify the probably eye irritancy potential of test items. In the case where the result indicates Non-irritant or Corrosive/Severely Irritating, then the test item can be classified. In all other cases the probable level of irritancy can be reported, but a regulatory in vivo rabbit eye irritation test is required for regulatory classification and labelling purposes.
UN GHS Classification Combinations of the three ICE Classes
No Category 3×I
2×I, 1×II
No prediction can be made Other combinations
Category 1 3×IV
2×IV, 1×III
2×IV, 1×II*
2×IV, 1×I*
Corneal opacity ≥ 3 at 30 min (in at least 2 eyes)
Corneal opacity = 4 at any time point (in at least 2 eyes)
Severe loosening of epithelium (in at least 1 eye)
Remark:*: combinations of categories less likely to occur
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- percent corneal swelling
- Remarks:
- 75 - 240 min
- Run / experiment:
- 1
- Value:
- >= 1.1 - <= 1.6
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- 1
- Value:
- 0.17
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- fluorescein retention score
- Run / experiment:
- 1
- Value:
- 0
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- percent corneal swelling
- Run / experiment:
- 2
- Value:
- 1.6
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- 2
- Value:
- 0.5
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- fluorescein retention score
- Run / experiment:
- 2
- Value:
- 0
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- The results from all eyes used met the quality control standards. The negative control and positive control results were within the historical data range in each experiment.
This study was considered to be valid.
The test item Selenium Disulphide showed no significant corneal effect in the first experiment. As the test item was solid, the negative results were confirmed by a second experiment according to the recommendations of the OECD No. 438 guideline. The second experiment confirmed the negative results. Therefore, based on these in vitro eye irritation tests in isolated chicken eyes with Selenium Disulphide, the test item was non-irritant, UN GHS Classification: No Category.
In experiment II. test item was stuck on all cornea surfaces after the post-treatment rinse, all cornea surfaces were cleared at 30 minutes after the post-treatment rinse. In each experiment positive control material was stuck on all cornea surfaces after the posttreatment rinse, the cornea surfaces were not cleared at 240 minutes after the post-treatment rinse.
No other morphological effect was observed in the study.
Any other information on results incl. tables
Test Item Experiment I |
||
Observation |
Value |
ICE Class |
Mean maximum corneal swelling at up to 75 min |
1.1 % |
I |
Mean maximum corneal swelling at up to 240 min |
1.6 % |
I |
Mean maximum corneal opacity |
0.17 |
I |
Mean fluorescein retention |
0.00 |
I |
Other Observations |
None |
|
Overall ICE Class |
3xI |
Test Item Experiment II |
||
Observation |
Value |
ICE Class |
Mean maximum corneal swelling at up to 75 min |
1.6 % |
I |
Mean maximum corneal swelling at up to 240 min |
1.6 % |
I |
Mean maximum corneal opacity |
0.50 |
I |
Mean fluorescein retention |
0.00 |
I |
Other Observations |
Test item was stuck on all cornea surfaces after the post-treatment rinse. The cornea surfaces (3/3) were cleared at 30 minutes after the post-treatment rinse. |
|
Overall ICE Class |
3xI |
Positive Control Experiment I |
||
Observation |
Value |
ICE Class |
Mean maximum corneal swelling at up to 75 min |
10.9% |
II |
Mean maximum corneal swelling at up to 240 min |
25.1% |
III |
Mean maximum corneal opacity |
4.00 |
IV |
Mean fluorescein retention |
3.00 |
IV |
Other Observations |
Imidazole was stuck onallcornea surfaces after the post- treatment rinse.The cornea surfaces (3/3) were not clearedat 240 minutes after the post-treatment rinse. |
|
Overall ICE Class |
1xIII 2xIV |
Positive Control Experiment II |
||
Observation |
Value |
ICE Class |
Mean maximum corneal swelling at up to 75 min |
10.3% |
II |
Mean maximum corneal swelling at up to 240 min |
25.5% |
III |
Mean maximum corneal opacity |
4.00 |
IV |
Mean fluorescein retention |
3.00 |
IV |
Other Observations |
Imidazole was stuck on all cornea surfaces after the post- treatment rinse.The cornea surfaces (3/3) were not cleared at 240 minutes after the post-treatment rinse. |
|
Overall ICE Class |
1xIII 2xIV |
The positive control Imidazole was classified as severely irritating, UN GHS Classification:Category 1.
Negative Control Experiment I |
||
Observation |
Value |
ICE Class |
Mean maximum corneal swelling at up to 75 min |
0.0% |
I |
Mean maximum corneal swelling at up to 240 min |
0.0% |
I |
Mean maximum corneal opacity |
0.00 |
I |
Mean fluorescein retention |
0.00 |
I |
Other Observations |
None |
|
Overall ICE Class |
3xI |
Negative Control Experiment II |
||
Observation |
Value |
ICE Class |
Mean maximum corneal swelling at up to 75 min |
0.0% |
I |
Mean maximum corneal swelling at up to 240 min |
0.0% |
I |
Mean maximum corneal opacity |
0.00 |
I |
Mean fluorescein retention |
0.00 |
I |
Other Observations |
None |
|
Overall ICE Class |
3xI |
The negative control Physiological saline was classified as non-irritating, UN GHS Classification: No Category
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Based on the in vitro eye irritation assays in isolated chicken eyes with Selenium Disulphide, it was concluded that the test item was non-irritant.
UN GHS Classification: No Category. - Executive summary:
An in vitro eye irritation study of the test item was performed in isolated chicken’s eyes. The irritation effects of the test item were evaluated according to the OECD No. 438 guideline (26 July 2013).
In each experiment after the zero reference measurements, the eye was held in horizontal position and 30 mg test item was applied onto the centre of the cornea in such a way that the entire surface of the cornea was covered. After 10 seconds, the surface was rinsed with physiological saline. Positive control eyes were treated with 30 mg powdered Imidazole. The negative control eye was treated with 30 µL of physiological saline (0.9% (w/v) NaCl solution). In each experiment, three test item treated eyes, three positive control treated eyes and one negative control treated eye were examined.
The results from all eyes used in the study met the quality control standards. The negative control and positive control results were within the historical control data range in each experiment. Thus, the experiment was considered to be valid.
Experiment I: No significant corneal swelling (mean ≤5%) was observed during the four-hour observation period on test item treated eyes. No significant cornea opacity change (severity 0.5) was observed on one eye. No fluorescein retention change was noted on three eyes.
Experiment II: No significant corneal swelling (mean ≤5%) was observed during the four-hour observation period on the test item treated eyes. No significant cornea opacity change (severity 0.5) was observed on three eyes. No fluorescein retention change was noted on three eyes. Test item was stuck on all cornea surfaces after the post-treatment rinse. All cornea surfaces were cleared at 30 minutes after the post-treatment rinse.
Based on the in vitro eye irritation assays in isolated chicken eyes with Selenium Disulphide, it was concluded that the test item was non-irritant, UN GHS Classification: No Category.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.