Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From May to June 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Reliability 1
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
static method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: CF02
- Expiration date of the lot/batch: 31.01.2019
- Purity test date: not available

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: refrigerated (2 to 8°C)
- Stability under test conditions: not available
- Solubility and stability of the test substance in the solvent/vehicle: not applicable
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: not applicable

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: none
- Preliminary purification step (if any): none
- Final dilution of a dissolved solid, stock liquid or gel: not applicable
- Final preparation of a solid: not applicable

OTHER SPECIFICS: none

Key result
Temp.:
20 °C
Vapour pressure:
21.8 Pa

Full test results

Temp/°C

Temp / K

P/mbar

**P/Pa

Run 1

*20

293.15

21.73

2173

20.0

293.15

22

2200

29.9

303.15

37.6

3760

40.6

313.75

71.9

7190

50.1

323.25

112.6

11260

Run 2

*20

293.15

21.48

2148

20.1

293.25

21.6

2160

30.3

303.45

39.3

3930

40.2

313.35

67.8

6780

50.0

323.15

112.1

11210

 *Determined by extrapolation

**Calculated

Comments

Run 1: 10.39 g of sample used. Prior to testing the sample was placed in a fridge for approximately 40 hours. The sample was degassed for 5 minutes and a pressure of 7 mbar was obtained. This is significantly higher than the guideline suggested < 0.02 mbar. The sample continued to outgas, possibly due to water boiling at low pressure.

Run 2: 10.46 g of sample used. Prior to testing the sample was placed in a fridge for approximately 64 hours. The sample was degassed for 5 minutes and a pressure of 2 mbar was obtained. This is significantly higher than the guideline suggested < 0.02 mbar. The sample continued to outgas, possibly due to water boiling at low pressure.

Conclusions:
In a static method test, conducted according to EU Regulation (EC) 440/2008, Annex Part a test A4, a vapor pressure of 21.8 Pa was determined for Coffee, bean, roasted ext. at 20°C
Executive summary:

A static method, conducted according to EU Regulation (EC) 440/2008, Annex Part A test A4, was performed to determine the vapor pressure of Coffee, bean, roasted, ext.

Coffee, bean, roasted, ext. was placed in the glass chamber connected to a vacuum system linked with pressure monitors enabling the reading of any pressure/ vacuum of the contents of the static glassware. A suitable manometer liquid was placed in U-tube. The system was evacuated when the optimum vacuum was observed. The glassware was then isolated from the vacuum system and positioned in the constant temperature bath set to a desired starting temperature. As the static apparatus and its contents approached temperature equilibrium in the bath, the levels of the manometer liquid were balanced with pressure. This procedure was repeated until the system reached temperature and pressure equilibrium (i.e., no significant change in temperature or pressure were observed). The temperature and pressure displayed on the pressure monitors were then recorded. The temperature was subsequently set to a higher temperature and the procedure was repeated until enough data points were obtained.

A vapor pressure of 21.8 Pa was determined for Coffee, bean, roasted, ext. at 20°C

Description of key information

Vapor pressure: 21.8 Pa at 20°C

Key value for chemical safety assessment

Additional information

A static method, conducted according to EU Regulation (EC) 440/2008, Annex Part A test A4, was performed to determine the vapor pressure of Coffee, bean, roasted, ext.

A vapor pressure of 21.8 Pa was determined for Coffee, bean, roasted, ext. at 20°C.