Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-05-10 to 2017-05-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
- Appearance/Physical state: Pale brown powder
- Storage condition of test material: Room temperature, in the dark
- Expiry: 28 November 2018
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item has been determined to be not highly flammable as it did not propagate combustion over 200 mm.
Executive summary:

Flammability (Solids). Not highly flammable, using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied

Description of key information

Flammable solids:

The test item has been determined to be not highly flammable as it did not propagate combustion over 200 mm.

Pyrophoric solids:

The study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied.

Substances / mixtures which in contact with water emit flammable gases:

The study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Flammable solids:

Substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period.

Therefore in accordance with Regulation (EC) No. 1272/2008 section 2.7.2.1, this substance should not be classified as flammable solids.

Pyrophoric solids:

The substance is known to be stable at room temperature for prolonged periods of time (days).

Therefore, in accordance with Regulation (EC) No. 1272/2008 section 2.10.4, the classification procedure for pyrophoric solids need not be applied.

Substances / mixtures which in contact with water emit flammable gases:

The chemical structure of the substance or mixture does not contain metals or metalloids.

Therefore in accordance with Regulation (EC) No. 1272/2008 section 2.12.4.1(a), the classification procedure for this class need not be applied.