Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18-21/06/2019
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Remarks:
Fraunhofer
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Batch: B526734
Key result
Percentile:
D10
Mean:
ca. 2.296 µm
St. dev.:
10.41
Key result
Percentile:
D50
Mean:
ca. 10.34 µm
St. dev.:
10.41
Key result
Percentile:
D90
Mean:
ca. 28.31 µm
St. dev.:
10.41
Conclusions:
D(50) of Penicillin V Potassium is 10.34 µm
Executive summary:

Particle Size distrubution results, measured by means of a LS Particle Size Analyzer (Fraunhofer optical method) is as follow:


D(10): 2.296 µm - D(50): 10.34 µm - D(90): 28.31 µm

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 May 2019 - 05 June 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other:
Version / remarks:
• CIPAC MT 59 Sieve Analysis
• CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules
• CIPAC MT 169 Tap Density of Water Dispersible Granules
Principles of method if other than guideline:
Sieve analysis consists of the quantitative separation of test item into fractions of different particle size ranges by using of machine sieving method.
The test item was weighed into a beaker (W g) and poured into the measuring cylinder and fitted the rubber bung into the cylinder without jolting.
It was carefully put in the dropping box and the timing device was started.
With the thumb and forefinger of one hand the upper part of the cylinder was held and, during 1 second it was lifted up to 25 mm height. At the beginning of the next second, the cylinder was smartly released by quickly and completely withdrawing the thumb and forefinger. 50 counted drops were completed.
Then the cylinder was removed immediately from the dropping box, the volume was noted to the nearest 1 mL (V mL).
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
No.:
#1
Size:
< 45 µm
Distribution:
ca. 0.03 %
No.:
#2
Size:
>= 45 - < 63 µm
Distribution:
ca. 0.15 %
No.:
#3
Size:
>= 63 - < 100 µm
Distribution:
ca. 0.04 %
No.:
#4
Size:
>= 100 - < 250 µm
Distribution:
ca. 0.39 %
No.:
#5
Size:
>= 250 - < 500 µm
Distribution:
ca. 3.3 %
No.:
#6
Size:
>= 500 - < 1 000 µm
Distribution:
ca. 20.92 %
No.:
#7
Size:
>= 1 000 - < 2 000 µm
Distribution:
ca. 75.17 %
No.:
#8
Size:
>= 2 000 - < 4 000 µm
Distribution:
ca. 0.01 %
No.:
#9
Size:
> 4 000 µm
Distribution:
ca. 0 %
Conclusions:
Sieve analysis consists of the quantitative separation of test item into fractions of different particle size ranges by using of machine sieving method.
Executive summary:

Machine sieving test was carried out using the following test sieves 4, 2, 1 mm, 500, 250, 100, 63 and 45 μm.

The sieve size (µm) which passes less than 10 % of the charged substance is 250 µm.

The sieve size (µm) which passes more than 95 % of the charged substance is 2000µm

The mean particle size (by mass) is between 250 µm and 2000 µm.

Description of key information

Particle Size distribution of Penicillin V Potassium has been analyzed with two techniques:


A Machine sieving test carried out using the following test sieves 4, 2, 1 mm, 500, 250, 100, 63 and 45 μm.


And a Beckman Coulter Laser using Fraunhofer Optical Method.


 

Additional information