Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-10-13 to 2016-02-10
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: IEC 60079-20-1, Section 7
Deviations:
yes
Remarks:
With 5°C inrements rather than the specified 2°C increments
GLP compliance:
yes
Key result
Auto-ignition temperature:
405 °C
Atm. press.:
>= 747 - <= 756 mm Hg

Room temperature: 21 - 22°C Atmospheric pressure: 747 - 756 mmHg Sample preparation: tested as received

The results, giving the lowest ignition temperature and corresponding no-ignition temperatures obtained from five test series.

Sample quantities from 25, 50, 70, 100 and 150 µL were tested at 400°C with an ignition delay > 300 s. There was no ignition observed.

Only when a 50µL sample was tested at 405°C an ignition occured with an ignition delay of 10 s.

Conclusions:
The Auto-Ignition Temperature (AIT) of the test substance = 405 ± 20°C.
Executive summary:

Room temperature: 21 - 22°C Atmospheric pressure: 747 - 756 mmHg Sample preparation: tested as received

The results, giving the lowest ignition temperature and corresponding no-ignition temperatures obtained from five test series.

Sample quantities from 25, 50, 70, 100 and 150µL were tested at 400°C with an ignition delay > 300 s. There was no ignition observed.

Only when a 50µL sample was tested at 405°C an ignition occured with an ignition delay of 10 s.

Description of key information

A single study for the autoignition temperature was available, conducted according to IEC 60079 -20 -1 under GLP.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
405 °C

Additional information