Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
agglomerate
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
4-pyridylamine
EC Number:
207-987-9
EC Name:
4-pyridylamine
Cas Number:
504-24-5
Molecular formula:
C5H6N2
IUPAC Name:
nickel
Test material form:
solid: particulate/powder

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D50
Mean:
222.9 µm
Remarks on result:
other: st.dev not specified
Key result
Percentile:
D10
Mean:
28.8 µm
Remarks on result:
other: st.dev not specified
Key result
Percentile:
D90
Mean:
662.1 µm
Remarks on result:
other: st.dev not specified

Any other information on results incl. tables

Two test series of 3 measurements each were performed with the test item.

Figure 1 and Figure 2 show the results of both test series. On the left y-axis the fraction distribution and on the right y-axis the cumulative distribution is shown.

 

Test series 1 (Figure 1):

D10:       28.5 µm

D50:       221.8 µm       (Median diameter)

D90:       657.7 µm

 

Test series 2 (Figure 2):

D10:       29.1 µm

D50:       223.9 µm       (Median diameter)

D90:       666.4 µm

 

Average

D10:       28.8 µm

D50:       222.9 µm       (Median diameter)

D90:       662.1 µm

Applicant's summary and conclusion

Conclusions:
The test item 4-Aminopyridine has a median particle size D50 = 222.9 µm, which was determined by laser diffraction measurement in accordance to ISO 13320 (2009) and OECD 110 (1981) method.
Executive summary: