Study period:
10 Mar 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
Storage conditions: ambient temperature (10 – 30 °C), dry
Percentile:
D50
Mean:
377.8 µm
St. dev.:
1.2
Remarks on result:
other: Individual results: 377.0 and 378.7 µm
Percentile:
D10
Mean:
174.9 µm
St. dev.:
0.85
Remarks on result:
other: Individual results: 174.3 and 175.5 µm
Percentile:
D90
Mean:
655.5 µm
St. dev.:
1.27
Remarks on result:
other: Individual results: 654.6 and 656.4 µm
No.:
#1
Size:
< 10 µm
Distribution:
0.51 %
Remarks on result:
other: Individual results see table
No.:
#2
Size:
< 10 µm
Distribution:
0.49 %
Remarks on result:
other: Individual results see table

Results
Laser diffraction
Median values were calculated from unrounded values.

The median particle size L50(D (v, 0.5): 50% of particle volume or particle mass with lower particle diameter) deduced from these distributions were:
1sttest series L50= 377.0 µm; 2ndtest series L50= 378.7 µm
The average of the median particle size: L50= 377.8 µm

The particle size L10(D (v, 0.1): 10% of particle volume or particle mass with lower particle diameter) deduced from these distributions were:
1sttest series: L10= 174.3 µm; 2ndtest series: L10= 175.5 µm
The average of the particle size: L10= 174.9 µm

The particle size L90(D (v, 0.9): 90% of particle volume or particle mass with lower particle diameter) deduced from these distributions were:
1sttest series: L90= 654.6 µm; 2ndtest series: L90= 656.4 µm
The average of the particle size: L90= 655.5 µm

The particle size distribution showed a polymodal distribution. The maximum was seen at ca. 400 µm and a shoulder at ca. 70 µm.

Description of key information

D10: 174.9 µm

D50: 377.8 µm

D90: 655.5 µm

(OECD 110, Laser Diffraction/Scattering)

Additional information

The particle size distribution showed a polymodal distribution. The maximum was observed at approximately 400 µm and a shoulder at approximately 70 µm.