Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 Jul to 28 Jul 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)
Auto-ignition temperature:
230 °C
Atm. press.:
1 013 hPa

Preliminary test

Volume of test item injected in the oven: 70 µL

 

Temperature of the assay (°C)

Auto-ignition

Maximal temperature of the air recorded in the centre of the test flask after auto-ignition (°C)

Atmospheric pressure (kPa)

Relative humidity (%)

Assay No.

Observed

Corrected

Y / N

Lag (s)

Observed

Corrected

1

97

97

No

/

/

/

98.5

46

2

155

155

No

/

/

/

98.5

44

3

203

203

No

/

/

/

98.5

47

4

252

252

Yes

53

271

272

98.4

46

5

237

237

Yes

17

261

262

98.4

45

6

228

228

No

/

/

/

98.4

44

7

231

231

No

/

/

/

98.3

41

 

The auto-ignition temperature was situated between 231 °C and 237 °C (corrected values).


Main test

Volume of test item injected in the oven: 70 µL

Only the auto-ignition runs for each assay are summarised in the following table

 

Auto-ignition temperature (°C)

Auto-ignition

Maximal temperature of the air recorded in the centre of the test flask after auto-ignition (°C)

Atmospheric pressure (kPa)

Relative humidity (%)

Assay No.

Observed

Corrected

Lag (s)

Observed

Corrected

1

234

234

21

260

261

98.4

43

2

233

233

37

257

257

98.4

44

3

235

235

22

259

259

98.4

41

4

236

236

17

261

262

98.3

40

5

237

237

16

263

264

98.3

40

 

Conclusion

The lowest value of the main series was 233 °C ± 3 °C (corrected temperature) and the auto-ignition temperature of the test item was 230 °C (reduced down to the next lower multiple of 5 °C).

Conclusions:
An auto-ignition temperature of 230 °C at 1013 hPa was determined in a reliable study conducted according to an appropriate test protocol.

Description of key information

Dichlorododecylmethylsilane: 230 °C (measured)

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
230 °C

Additional information

An auto-ignition temperature of 230°C at 1013 hPa was obtained for the parent substance according to EU test method A.15.