Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
69 °C
Atm. press.:
1 013 mBar
Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The flash point of the test item was determined to be 69 °C.
Executive summary:

A study was conducted according to ISO 3679 to determine flash point of the test item using a rapid equilibrium closed cup method. The flash point was determined to be at 69.0 °C at 1013 mbar. Therefore, the test item is classified as Category 4 Flammable liquid according to GHS criteria.

Description of key information

The flash point of the test item was determined to be 69 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
69 °C

Additional information

A study was conducted according to ISO 3679 to determine flash point of the test item using a rapid equilibrium closed cup method. The flash point was determined to be at 69.0 °C at 1013 mbar. Therefore, the test item is classified as Category 4 Flammable liquid according to GHS criteria. The test item is not classified with regard to CLP Regulation (EC) No 1272/2008.