Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 204-075-2 | CAS number: 115-25-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
![](https://echa.europa.eu/o/diss-blank-theme/images/factsheets/A-REACH/factsheet/print_toxicological-information.png)
Acute Toxicity: inhalation
Administrative data
- Endpoint:
- acute toxicity: inhalation
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1969
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- significant methodological deficiencies
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 969
- Report date:
- 1969
Materials and methods
Test guideline
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 403 (Acute Inhalation Toxicity)
- Deviations:
- yes
- Remarks:
- The limited information on the protocol does not allow verification of strict adherence to the guideline.
- GLP compliance:
- no
- Test type:
- fixed concentration procedure
- Limit test:
- no
Test material
- Reference substance name:
- Octafluorocyclobutane
- EC Number:
- 204-075-2
- EC Name:
- Octafluorocyclobutane
- Cas Number:
- 115-25-3
- Molecular formula:
- C4F8
- IUPAC Name:
- octafluorocyclobutane
Constituent 1
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source of test material: Organic Chemmicals Department of Jackson Laboratory.
- Expiration date and batch number: None given
- Purity test date: None given
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition & Stability of test material: not described in the report.
- Reactivity of the test substance with the solvent/vehicle /test medium: None
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: Houseline air was used as a diluent to give the desired atmospheric concentration.
- Preliminary purification step: Unsaturates were removed from the sample Freon C-318 ® .
Test animals
- Species:
- rat
- Strain:
- other: ChR-CD
- Sex:
- male
- Details on test animals or test system and environmental conditions:
- TEST ANIMALS
- Number : 6
- Source: not described in the report
- Age at study initiation: not described in the report
- Weight at study initiation: 258 to 268 grams
- Fasting period before study: not described in the report
- Housing: not described in the report
- Diet: not described in the report
- Water: not described in the report
- Acclimation period: not described in the report
ENVIRONMENTAL CONDITIONS
Not described in the report (no specific data on temperature, humidity or photoperiod).
Administration / exposure
- Route of administration:
- inhalation: gas
- Type of inhalation exposure:
- whole body
- Vehicle:
- air
- Details on inhalation exposure:
- GENERATION OF TEST ATMOSPHERE / CHAMBER DESCRIPTION
- Exposure apparatus: chamber (whole body)
- Exposure chamber volume: 16-liter exposure chamber
- Method of conditioning air: The test material was metered from an inverted cylinder into a heated copper coil.
TEST ATMOSPHERE
- Brief description of analytical method and equipment used: During the test, gas samples were taken every half hour from chamber exhaust port for atmosphere analysis. A triton X-100 column was used to separate the gases. Triton X-100 column is a Chromasorb ® W stainless steel column with 1/8'' diameter and 10' lenght, used in a Varian Aerograph Model 600-D gas chromatograph.
- Samples taken from breathing zone: yes
VEHICLE
- Composition of vehicle: Housline air used as a diluent
- Concentration of test material in vehicle: 50,000 ppm
- Analytical verification of test atmosphere concentrations:
- yes
- Duration of exposure:
- 4 h
- Concentrations:
- 5% (50000 ppm, v/v)
- No. of animals per sex per dose:
- 6 male rats
- Control animals:
- no
- Details on study design:
- - Duration of observation period following administration: not detailed in study report
- Frequency of observations and weighing: not detailed in study report
- Necropsy of survivors performed: no
- Clinical signs including body weight: Irregular breathing; red ears, Normal weight gain
Results and discussion
- Preliminary study:
- None
Effect levels
- Key result
- Sex:
- male
- Dose descriptor:
- LC50
- Effect level:
- > 50 000 ppm
- Based on:
- test mat.
- Exp. duration:
- 4 h
- Mortality:
- Mortality ratio: 0/6
- Clinical signs:
- irregular respiration
- Body weight:
- Normal wright gain
- Gross pathology:
- None
- Other findings:
- Other observation: red ears
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- At the 5% level (50000 ppm, v/v), Freon C-318 (octafluorocyclobutane) purified by the procedure used for this sample was not toxic to rats during or after a four-hour exposure by inhalation.
- Executive summary:
Acute toxicity of test material Freon® C-318 (octafluorocycobutane) was investigated in expermital test involving six male ChR-CD rats. Rats were exposed to a unique concentration of 50000 ppm of purified test material in a exposure chamber for four hours.
At the 5% level (50000 ppm, v/v), Freon C-318 (octafluorocyclobutane) purified by the procedure used for this sample was not toxic to rats during or after a four-hour exposure by inhalation.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.