Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 618-014-6 | CAS number: 874288-98-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Explosiveness
Administrative data
Link to relevant study record(s)
- Endpoint:
- explosiveness, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- October 2016 - November 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.14 (Explosive properties)
- Deviations:
- no
- GLP compliance:
- yes
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 1609080930
- Purity: 98.4% - Key result
- Parameter:
- sensitiveness to impact: impact energy (J)
- Remarks on result:
- not sensitive to impact using an impact energy of 40 J
- Key result
- Parameter:
- thermal sensitivity - Koenen test: diameter of the orifice plate
- Remarks:
- 6.0 mm
- Remarks on result:
- not thermal sensitive if heated under defined confinement
- Key result
- Parameter:
- thermal sensitivity - Koenen test: limiting diameter (mm)
- Remarks:
- 2.0 mm
- Remarks on result:
- not thermal sensitive if heated under defined confinement
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test item is not considered to possess explosives properties according to GHS Criteria.
- Executive summary:
The explosive properties of 1,2-dichloro-1-[difluoro(trifluoromethoxy)methoxy]-1,2,2-trifluoroethane have been assessed in a GLP study conducted according to a recognized guideline (EU Method A.14).
As requested by the guideline followed two tests have been performed on the liquid test item: BAM Fallhammer (mechanical sensitivity to shock) test and Koenen tube (thermal sensitivity).
Based on the results obtained in these tests, the test item is not considered to possess explosives properties. The test item is not classified as GHS criteria are not met.
Reference
BAM Fallhammer test:
The test item sample did not exhibit a reaction at 40 J. The test result is therefore considered as negative.
Koenen Tube test:
The sample did not exhibit an explosion during any of the tests. The test result is therefore considered as negative
Description of key information
One reliable key study (Klimisch 1) is available.
In the study the explosive properties of the test item was assessed according to a recognised guideline (EU Method A.14) under GLP.
No deviations from the guideline were observed during the study.
Key value for chemical safety assessment
- Explosiveness:
- non explosive
Additional information
As requested by the guideline followed two tests have been performed on the liquid test item: BAM Fallhammer (mechanical sensitivity to shock) test and Koenen tube (thermal sensitivity).
1,2-dichloro-1-[difluoro(trifluoromethoxy)methoxy]-1,2,2-trifluoroethane did not exhibit explosive properties during any of the tests. Therefore the test item is not considered as explosives and is not classified.
Justification for classification or non-classification
1,2-dichloro-1-[difluoro(trifluoromethoxy)methoxy]-1,2,2-trifluoroethane did not exhibit explosive properties during any of the tests. Therefore the test item is not considered as explosives and is not classified.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.