Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 807-461-4 | CAS number: 1489170-67-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin sensitisation
Administrative data
- Endpoint:
- skin sensitisation: in vivo (LLNA)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 014
- Report date:
- 2014
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 429 (Skin Sensitisation: Local Lymph Node Assay)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.42 (Skin Sensitisation: Local Lymph Node Assay)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of study:
- mouse local lymph node assay (LLNA)
Test material
- Reference substance name:
- sodium 4-[(4-chlorobenzoyl)amino]benzoate
- EC Number:
- 807-461-4
- Cas Number:
- 1489170-67-3
- Molecular formula:
- C14H9ClNNaO3
- IUPAC Name:
- sodium 4-[(4-chlorobenzoyl)amino]benzoate
- Test material form:
- solid: particulate/powder
- Remarks:
- migrated information: powder
- Details on test material:
- - Storage condition of test material: room temperature in the dark
- Description: white powder
Constituent 1
In vivo test system
Test animals
- Species:
- mouse
- Strain:
- other: CBA/Ca (CBA/CaOlaHsd)
- Sex:
- female
- Details on test animals and environmental conditions:
- TEST ANIMALS
- Source: Female CBA/Ca (CBA/CaOlaHsd) strain mice were supplied by Harlan Laboratories UK Ltd., Oxon, UK
- Age at study initiation: eight to twelve weeks
- Weight at study initiation: 15 to 23 g
- Housing: individually housed in suspended solid floor polypropylene cages furnished with softwood woodflakes
- Diet (e.g. ad libitum) and water (e.g. ad libitum): Free access to mains tap water and food (2014C Teklad Global Rodent diet supplied by Harlan Laboratories UK Ltd., Oxon, UK) was allowed throughout the study
- Acclimation period: at least five days
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 19 to 25 °C
- Humidity (%): 30 to 70%
- Air changes (per hr): approximately fifteen changes per hour
- Photoperiod (hrs dark / hrs light): twelve hours continuous light (06.00 to 18.00) and twelve hours darkness
Study design: in vivo (LLNA)
- Vehicle:
- other: 1% pluronic L92 in distilled water
- Concentration:
- Preliminary screening test: maximum attainable concentration of 10% w/w in 1% pluronic L92 in distilled water
Main test: 10%, 5% or 2.5% (w/w) in 1% pluronic L92 in distilled water - No. of animals per dose:
- Preliminary screening test: one mouse
Main test: groups of four mice - Details on study design:
- RANGE FINDING TESTS:
- Compound solubility: Not stated in report
- Irritation: None
- Lymph node proliferation response: The proliferation response of lymph node cells was expressed as the number of radioactive disintegrations per minute per lymph node (disintegrations per minute/node) and as the ratio of 3HTdR incorporation into lymph node cells of test nodes relative to that recorded for the control nodes (Stimulation Index).
MAIN STUDY
ANIMAL ASSIGNMENT AND TREATMENT:
- Name of test method: Local Lymph Node Assay in the Mouse
- Criteria used to consider a positive response: The test item will be regarded as a sensitizer if at least one concentration of the test item results in a threefold or greater increase in3HTdR incorporation compared to control values. Any test item failing to produce a threefold or greater increase in3HTdR incorporation will be classified as a non-sensitizer.
TREATMENT PREPARATION AND ADMINISTRATION:
Groups of four mice were treated with the test item at concentrations of 10%, 5% or 2.5% w/w in 1% pluronic L92 in distilled water. The preliminary screening test suggested that the test item would not produce systemic toxicity or excessive local skin irritation at the highest suitable concentration. The mice were treated by daily application of 25 µL of the appropriate concentration of the test item to the dorsal surface of each ear for three consecutive days (Days 1, 2, 3). The test item formulation was administered using an automatic micropipette and spread over the dorsal surface of the ear using the tip of the pipette.
A further group of four mice received the vehicle alone in the same manner.
3H-Methyl Thymidine Administration:
Five days following the first topical application of the test item or vehicle (Day 6) all mice were injected via the tail vein with 250 µL of phosphate buffered saline (PBS) containing 3H-methylthymidine (3HTdR: 80 µCi/mL, specific activity 2.0 Ci/mmoL, ARC UK Ltd) giving a total of 20 µCi to each mouse. - Positive control substance(s):
- hexyl cinnamic aldehyde (CAS No 101-86-0)
Results and discussion
- Positive control results:
- The Stimulation Index expressed as the mean radioactive incorporation for each treatment group divided by the mean radioactive incorporation of the vehicle control group are as follows:
Concentration (% v/v) in 1% pluronic L92 in distilled water: 25
Stimulation Index: 4.66
Result: Positive
Conclusion: alpha Hexylcinnamaldehyde was considered to be a sensitiser under the conditions of the test.
In vivo (LLNA)
Resultsopen allclose all
- Parameter:
- SI
- Remarks on result:
- other: 2.5 % concentration: 0.74 5 % concentration: 1.04 10 % concentration: 1.04
- Parameter:
- other: disintegrations per minute (DPM)
- Remarks on result:
- other: 2.5 % concentration: 9329.85 5 % concentration: 13156.43 10 % concentration: 13153.05
Applicant's summary and conclusion
- Interpretation of results:
- not sensitising
- Remarks:
- Migrated information Criteria used for interpretation of results: other: EU GHS
- Conclusions:
- The test substance was considered to be non-sensitising under the conditions of this test. The study was performed under GLP according to OECD guideline 429 and EU Method B.42 and therefore reliability of Klimisch 1 has been assigned.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.